EZC100H1032 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC100H1032 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width25 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC100H1032 is a 1-pole EasyPact EZC100H thermal-magnetic circuit breaker rated 32 A at 50 °C (32 A at 40 °C per the In rating). It carries a 25 kA Icu breaking capacity at 220–240 V AC 50/60 Hz per IEC 60947-2, stepping down to 5 kA at 380–400 V AC and 10 kA at 125 V DC 1P.

Category A utilization (no intentional short-time delay) means it trips instantaneously on fault — suited for distribution feeder duty, not selective coordination downstream of a larger breaker.

Fixed mounting on a backplate, 25 mm width per pole, 60 mm depth, 130 mm height. Front connection both top and bottom. IP20 finger-safe terminals, IK07 impact resistance. Pollution degree 3 environment — install in a panel that keeps conductive dust and condensation off live parts.