Skip to main content
Schneider Electric EZC250F3175

Schneider Electric EZC250F3175 EasyPact EZC250F Circuit Brea

MPN EZC250F3175
Obsolete

Schneider Electric EasyPact EZC250F series, EZC250F3175, 3-pole circuit breaker, 175 A thermal-magnetic TM-D trip unit, 10 kA Icu at 440 V AC, fixed mount, front connections.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC250F3175 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC250F3175 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width105 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC250F3175 is a 3-pole EasyPact EZC250F moulded-case circuit breaker with a thermal-magnetic TM-D trip unit rated 175 A at 40 °C. The TM-D trip gives you fixed thermal overload protection (the bimetal element) and fixed magnetic short-circuit pickup; no adjustment dials, so set your coordination study around those fixed thresholds. Breaking capacity is the real selector here. At 440 V AC it interrupts 10 kA Icu (IEC 60947-2). At 400–415 V AC that climbs to 15 kA Icu, and at 380 V AC to 18 kA Icu. For 220–240 V AC circuits it handles 25 kA Icu. On DC: 5 kA Icu at 125 V DC (1-pole) or 250 V DC (2-pole). The 'F' breaking capacity code tells you this is the standard-interrupting version of the EZC250F frame — not the high-breaking 'H' variant.

Dimensions: 105 mm wide, 165 mm high, 60 mm deep — fits a standard MCCB footprint in most distribution boards. IP20 finger-safe terminals; IK07 impact rating means it survives a 2 J hammer blow during panel work. Toggle control with positive contact indication — you can see and feel the contact position.

Compliance documentation is straightforward: the breaker carries IEC 60947-2, EN 60947-2, GB/T 14048.2, and JIS C8201-2-2 certifications. No earth-leakage protection built in; if you need that, you add an external Vigi module or use the EZC250F with earth-leakage option.

Category A utilization (no intentional short-time delay) means this breaker trips instantaneously on short-circuit — it's a feeder or branch-circuit protector, not a main breaker that needs selectivity with downstream devices via ST delay. Use it downstream of a main breaker or fuse that has a higher Icu rating and can coordinate. Mechanical durability of 10,000 cycles is typical for a distribution MCCB; fine for panel switching a few times a year, not for frequent motor-starting duty.

MPN
EZC250F3175