Skip to main content
Schneider Electric EZC250H4063

Schneider Electric EZC250H4063 EasyPact EZC250H Circuit Brea

MPN EZC250H4063
Active

Schneider Electric EasyPact EZC250H, circuit breaker, 4P, 63 A, TM-D trip unit, 25 kA Icu at 440 V AC, 10 kA Icu at 550 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC250H4063 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC250H4063 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The EZC250H4063 is a 4-pole EasyPact EZC250H molded-case circuit breaker from Schneider Electric, fitted with a TM-D thermal-magnetic trip unit rated 63 A at 50 °C. That thermal-magnetic technology means it handles two jobs in one device: the thermal element protects against sustained overloads (heating up and tripping on a slow curve), while the magnetic element catches short-circuits instantly. Let me show you why the breaking capacity matters here. At 440 V AC, the Icu is 25 kA; at 550 V AC it drops to 10 kA, and at 220–240 V AC it climbs to 85 kA. The 10 kA at 550 V is a safety margin for systems running at the upper end of the voltage range, but in practice most installations will land at the 440 V or 415 V level where you have the full 25 kA or 36 kA respectively. Is this clear enough for a junior? If your panel's SCCR study calls for 25 kA at 480 V, this breaker fits; if you need 50 kA at 480 V, you'd step up to the H- or L-frame. Mounting is fixed backplate — no DIN-rail adapter on this frame size. The 140 mm width and 165 mm height mean it occupies a standard MCCB footprint; you'll need a 35 mm connection pitch between phases on the busbar. Front-front connections (line and load both front-accessible) simplify busbar routing in a panel but mean the breaker isn't suitable for rear-connected switchboards without an adapter kit.

The breaker carries IEC 60947-2 certification (the main standard for molded-case circuit breakers), plus JIS C8201-2-2 and GB/T 14048.2 for Japanese and Chinese markets. The IP20 finger-safe protection on the front and IK07 impact resistance mean it's suitable for general-purpose industrial panels where accidental contact or minor impacts are a concern.

MPN
EZC250H4063