Skip to main content
Schneider Electric EZC250N44200

Schneider Electric EZC250N44200 EasyPact EZC250N 200A 4P Cir

MPN EZC250N44200
Obsolete

Schneider Electric EasyPact EZC250N series, EZC250N44200, 4-pole thermal-magnetic circuit breaker, 200 A rated current, 20 kA breaking capacity at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC250N44200 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC250N44200 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC250N44200 is a 4-pole EasyPact EZC250N thermal-magnetic circuit breaker rated 200 A at 40 °C (200 A at 50 °C on the trip unit). It carries a 20 kA Icu at 440 V AC — the N breaking capacity code — and is certified to IEC 60947-2. The TM-D trip unit provides short-circuit and overload protection; there is no integral earth-leakage module. It ships as a fixed-mount, front-connect unit with a toggle handle and positive contact indication. The kit is complete: no missing brackets or separate trip units to order.

The 20 kA Icu at 440 V AC is the headline fault-interruption figure for a 200 A frame in a distribution panel. At 380–415 V AC it rises to 25 kA, and at 220–240 V AC it reaches 50 kA — useful for high-fault locations near a transformer. On DC, it manages 20 kA at 125 V (1-pole) or 250 V (2-pole). The 8 kA Icu at 550 V AC is the ceiling for the rated operational voltage. For a Category A breaker (no intentional short-time delay), selectivity with downstream devices depends on the instantaneous trip threshold of the TM-D unit.

Fixed backplate mount, 35 mm connection pitch, front terminals top and bottom. Dimensions: 165 mm high, 140 mm wide, 60 mm deep. IP20 finger-safe enclosure; IK07 impact resistance. No neutral protection fitted — the 4t protected poles cover all four phases, with the neutral unprotected.

MPN
EZC250N44200