Skip to main content
Schneider Electric EZC400N3350

Schneider Electric EZC400N3350 EasyPact EZC400N 3P 400A Circ

MPN EZC400N3350
Obsolete

Schneider Electric EasyPact EZC400N, 3-pole molded case circuit breaker, 400 A rated current at 40 °C, TM-D thermal-magnetic trip unit, 36 kA Icu at 440 V AC, fixed mounting, front connections, black.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC400N3350 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC400N3350 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width185 mm
Height255 mm
Electrical life cyclesCategory A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC400N3350 is a 3-pole molded case circuit breaker from the EasyPact EZC400N range, rated 400 A at 40 °C with a TM-D thermal-magnetic trip unit. It provides short-circuit and overload protection for distribution feeders, with a breaking capacity of 36 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2. The trip unit is field-adjustable? No — the TM-D is a fixed thermal-magnetic unit; the magnetic trip is set at 3200 A (8x In). For a 400 A feeder, that gives a good balance between nuisance immunity and short-circuit protection.

Fixed mounting on a backplate, with front connections both top and bottom. Dimensions: 255 mm high, 185 mm wide, 140 mm deep. That's a compact footprint for a 400 A frame — fits in a standard distribution panel without needing a deep enclosure. IP20 finger-safe protection on the front, IK07 impact resistance. The toggle gives positive contact indication, so you can visually confirm the contact position.

MPN
EZC400N3350