Skip to main content
Schneider Electric EZC630H3500N

Schneider Electric EZC630H3500N EasyPact EZC630H, 630A, 50kA

MPN EZC630H3500N
Active

Schneider Electric EasyPact EZC630H, EZC630H3500N, 3P, 630 A at 40 °C, 50 kA Icu at 380 V AC, thermal-magnetic TM-D trip unit, fixed mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC630H3500N key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC630H3500N additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth110 mm
Width140 mm
Height255 mm
Electrical life cyclesCategory A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC630H3500N is a 3-pole EasyPact EZC630H moulded-case circuit breaker rated 630 A at 40 °C, with a thermal-magnetic TM-D trip unit. It provides short-circuit and overload protection for distribution applications, with a breaking capacity of 50 kA Icu at 380 V AC and 50/60 Hz per IEC 60947-2. The 630 A frame means it handles high-current feeds — main switchboard incomers, large motor control centre busbars, or transformer secondary protection — where the 50 kA fault level is common in industrial plant.

The magnetic trip is fixed at 6000 A, giving an instantaneous pickup of roughly 10× In — typical for distribution-grade MCCBs, meaning it clears high-impedance faults quickly but will ride through motor inrush on downstream starters. Breaking capacity is 50 kA Icu at 380 V, 440 V, and 400/415 V — the same 50 kA holds across the common industrial voltage band. At 220/230 V it rises to 70 kA. For a distribution board with a transformer secondary fault current of 45 kA, this breaker holds the line; above 50 kA you need the H- or L-frame variant. The breaker is Category A (no intentional short-time delay), so it trips instantaneously on fault — selectivity with downstream devices relies on current discrimination, not time grading. Mechanical durability is 10 000 cycles, electrical durability 3000 cycles at 415 V — adequate for a main breaker that operates a few times a year, but not for a switching duty like a welding machine or frequent motor start. The IP20 finger-safe enclosure and IK07 impact resistance protect against accidental contact and light mechanical shock inside the panel.

Fixed-mount via backplate — no DIN-rail adapter. The 140 mm width × 255 mm height × 110 mm depth footprint fits standard panel cutouts for 630 A frame MCCBs. Front connection both top and bottom; connection pitch is 45 mm. Toggle control with positive contact indication; the suitability-for-isolation mark (per IEC 60947-2) means the breaker can be used as a disconnecting means — no need for a separate isolator upstream.

MPN