Schneider Electric EZC630N44500N

Schneider Electric EasyPact EZC630N44500N 630A 4P MCCB, 36kA

MPN EZC630N44500N
Obsolete

Schneider Electric EasyPact EZC630N, 630A thermal-magnetic MCCB, 4 poles, 36 kA Icu at 440 V AC, TM-D trip unit, fixed mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC630N44500N key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC630N44500N additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width140 mm
Height255 mm
Electrical life cyclesCategory A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EasyPact EZC630N44500N is a 4-pole molded-case circuit breaker (MCCB) rated 630 A at 40 °C, built for distribution applications in commercial and industrial panels. It carries a TM-D thermal-magnetic trip unit — thermal for overload protection, magnetic for short-circuit — with a magnetic tripping threshold of 5000 A. The 36 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2 tells you it can safely interrupt a fault up to that level without welding contacts or cascading upstream. That's the number that governs selectivity coordination with downstream breakers.

Fixed backplate mount, front-front connections (line and load both front-accessible). The 140 mm width and 255 mm height mean it occupies a standard MCCB footprint on a backplate or inside a distribution cabinet. Connection pitch is 45 mm — lines up with common busbar systems. IP20 finger-safe terminals per IEC 60529; IK07 impact rating per EN 50102 means the enclosure shrugs off a 2 J hammer blow during installation.

MPN