Skip to main content
Schneider Electric EZCV250H44160

Schneider Electric EZCV250H44160 EasyPact EZCV250H, 160 A, 1

MPN EZCV250H44160
Obsolete

Schneider Electric EasyPact EZCV250H, molded case circuit breaker, 4P, 160 A at 40 °C, TM-D thermal-magnetic trip unit, 100 kA Icu at 240 V AC, with earth-leakage protection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZCV250H44160 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZCV250H44160 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth68 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The 4P configuration with earth-leakage protection (integral, not add-on) suits TN or TT systems where you need both overcurrent and ground-fault protection in one package.

Deployment context

Mounts on a backplate (fixed mounting, not DIN rail) with front connections both top and bottom. Pollution degree 3 per IEC 60947 covers industrial atmospheres with conductive or dry non-conductive pollution, typical of most control rooms and switchgear enclosures. The toggle handle provides positive contact indication — you can see and feel the contact position, which simplifies lockout/tagout verification.

Certified to GB/T 14048.2, EN/IEC 60947-2, and JIS C8201-2-2. The IEC 60947-2 listing covers the breaking capacity ratings and the isolation suitability mark — the breaker is certified for use as a disconnecting means (isolation function) per that standard. The IK07 impact rating (per EN 50102) means the enclosure withstands a 2 J impact, typical for industrial switchgear.

MPN
EZCV250H44160