Skip to main content
Schneider Electric EZS630F3500

Schneider Electric EZS630F3500 EasyPact EZS Circuit Breaker,

MPN EZS630F3500
Obsolete

Schneider Electric EasyPact EZS series, EZS630F3500, 3-pole circuit breaker, 500 A at 40 °C, TM-D thermal-magnetic trip unit, 40 kA Icu at 220/240 V AC, fixed mounting, front connections.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZS630F3500 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2
Insulation voltage ui690 V conforming to EN/IEC 60947-2
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to GB 14048.2 35 kA Icu at 440 V AC 50/60 Hz conforming to GB 14048.2
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

EZS630F3500 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth110 mm
Width182 mm
Height257 mm
Electrical life cycles8000 cycles 415 V In/2 conforming to EN/IEC 60947-2 8000 cycles 400 V In conforming to GB 14048.2
Mechanical life cycles15000 cycles conforming to EN/IEC 60947-2 10000 cycles conforming to GB 14048.2
Operating temperature-35...70 °C

Product details

The TM-D trip unit provides fixed long-time pickup at 1 In and a fixed instantaneous threshold of 5000 A, which is the magnetic trip point for short-circuit protection. For a distribution panel feeding a 500 A bus, this breaker sits as the main or a large feeder; the fixed trip settings mean no field adjustment — what you order is what protects the circuit. Breaking capacity is 40 kA Icu at 220/240 V AC and 36 kA Icu at 380/400 V AC, both per EN/IEC 60947-2. The 40 kA at 220 V covers North American 240 V split-phase distribution. Rated insulation voltage (Ui) is 690 V, and rated operational voltage (Ue) is 440 V AC. The 690 V Ui means the internal creepage and clearance distances are designed for a 690 V system, so the breaker can be used in 400/440 V circuits with full margin.

Fixed mounting on a backplate, with front connections on both the line and load sides. Neutral is on the left, which matters when aligning with a pre-drilled busbar or a downstream neutral bar.

MPN
EZS630F3500