Schneider Electric GV4L03N

GV4L03N TeSys Deca Motor Circuit Breaker, 3.5 A, 3P

MPN GV4L03N
Active

Schneider Electric TeSys Deca GV4L03N, 3-pole motor circuit breaker, 3.5 A rated current, magnetic-electronic trip, 100 kA breaking capacity at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4L03N key specifications
ParameterValue
Control typeRotary handle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3

All specifications

GV4L03N additional specifications
ParameterValue
ColorGrey (RAL 7016)
Depth165 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

The Schneider Electric GV4L03N is a 3-pole motor circuit breaker from the TeSys Deca range, rated at 3.5 A continuous current and designed for motor protection per IEC 60947-4-1. The 3.5 A rating means this breaker is sized for small motor loads — think fractional-horsepower pumps, fans, or conveyors on 400 V three-phase systems where the motor full-load current sits at or below that figure. The magnetic trip range of 21...49 A handles the inrush without nuisance tripping.

Breaking capacity and fault handling

Breaking capacity hits 100 kA Icu at 240 V AC and 50 kA at 415 V AC per IEC 60947-2. The breaker's role is protection and isolation, rated for 40,000 electrical cycles under AC-3 conditions at 440 V.

The EverLink BTR connectors on top accept 1.5...70 mm² solid or 1.5...50 mm² flexible cable; the bottom terminals go up to 95 mm² solid. Tightening torque is 9 N·m for the larger cable range, 5 N·m for the smaller — a torque wrench is worth using here to avoid terminal heating under continuous load. IP40 front face with IK07 impact resistance suits it for enclosed panel mounting where occasional tool drops or panel-door knocks are expected.

Compliance documentation covers EN/IEC 60947-2 and 60947-4-1, with a fire-resistance rating of 960 °C per IEC 60695-2-11 and climatic withstand per IACS for marine environments. The grey RAL 7016 housing is standard for the Deca range.

MPN