Schneider Electric GV4L12N

Schneider Electric GV4L12N TeSys Deca Motor Circuit Breaker,

MPN GV4L12N
Active

Schneider Electric TeSys Deca GV4L12N, 3-pole motor circuit breaker, 12.5 A rated current, magnetic-electronic trip, 100 kA breaking capacity at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4L12N key specifications
ParameterValue
Control typeRotary handle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C

All specifications

GV4L12N additional specifications
ParameterValue
Pollution degree3
ColorGrey (RAL 7016)
Depth165 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

The GV4L12N is a TeSys Deca motor circuit breaker from Schneider Electric, rated 12.5 A continuous (In) and built for 3-pole motor protection. The 12.5 A frame size means it's sized for a motor drawing around that full-load current—check the motor nameplate FLA against this number, not the motor power kW, because the kW table (3 kW at 400 V, up to 11 kW at 690 V) depends on your line voltage and motor efficiency. The magnetic trip is adjustable 75–175 A, so it handles inrush without nuisance tripping on a motor that size. Breaking capacity is 100 kA Icu at 240 V AC, 50 kA at 415 V, and 15 kA at 525 V—all per IEC 60947-2. That's high fault-current headroom for a 12.5 A device; it clears a bolted fault without upstream fuses needing to open, which simplifies coordination in a panel with a 50 kA SCCR requirement at 415 V. The utilisation category is AC-3 (IEC 60947-4-1), meaning it's rated for switching motor loads—starting and stopping under load, not just isolation.

This is a panel-mount device with EverLink BTR screw terminals—top accepts 1.5–70 mm² solid, bottom up to 95 mm² solid. Tightening torque is 9 N·m for the larger cable range (16–95 mm²), 5 N·m for 1.5–10 mm². IP40 front-of-panel protection means it's fine inside a clean enclosure but not for washdown zones. Mechanical durability is 40,000 cycles, electrical durability also 40,000 cycles at AC-3 at 440 V at full load current (In). Maximum operating rate is 25 cycles per hour—fine for a pump or conveyor start/stop duty, but not for high-speed jogging. The ambient operating range is -25 to 70 °C, storage -50 to 85 °C, and it's rated for operation up to 5000 m altitude without derating. Vibration tolerance is ±1 mm at 2–13.2 Hz and 0.7 gn at 13.2–100 Hz per IEC 60068-2-6, so it holds up on a panel mounted to a motor skid or compressor base.

MPN
GV4L12N