Skip to main content
Schneider Electric GV4LE03S

Schneider Electric GV4LE03S TeSys Deca Motor Circuit Breaker

MPN GV4LE03S
Active

Schneider Electric TeSys Deca GV4L motor circuit breaker, 3-pole, 3.5 A rated current, magnetic-electronic trip, breaking capacity up to 120 kA at 240 V AC.

$426.73 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE03S key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C

All specifications

GV4LE03S additional specifications
ParameterValue
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

The Schneider Electric GV4LE03S is a TeSys Deca GV4L motor circuit breaker — a 3-pole device rated at 3.5 A continuous, designed for motor protection under IEC 60947-4-1 and IEC 60947-2. Its magnetic-electronic trip unit provides short-circuit and overload protection in a single enclosure, with a magnetic tripping window of 21...49 A that clears faults before they damage downstream contactors or the motor itself. Breaking capacity reaches 120 kA Icu at 220...240 V AC, 100 kA at 380...415 V, and 30 kA at 500 V — figures that cover most industrial distribution panels without needing a current-limiting upstream breaker. At 660...690 V it still interrupts 10 kA, so it holds up on 690 V line-fed motors.

That's enough cross-section for the 3.5 A motor feed plus any tap-offs. IP40 enclosure with IK07 impact resistance suits clean indoor panels; the grey RAL 7016 housing resists marking. Operating altitude goes to 5000 m, and the ambient temperature range is -25...70 °C, so it handles unventilated enclosures near ovens or drives without derating.

Key ratings in context

Motor power coverage spans 0.55 kW to 2.2 kW depending on line voltage — 0.55 kW at 400...415 V, 0.75 kW at 500 V, 1.1 kW at 660...690 V, and 2.2 kW at 690 V. The 3.5 A rated current (In) is the continuous thermal setting; the magnetic trip (21...49 A) handles the start-up inrush without nuisance tripping. Electrical durability is rated at 40,000 cycles under AC-3 at 440 V at full load current — that's the motor-switching duty cycle. Mechanical endurance matches at 40,000 cycles. Maximum operating rate is 25 cycles per hour, so it's not intended for high-speed jogging or frequent reversing. Power dissipation per pole is 6.1 W, totalling about 18.3 W across all three poles at rated current. That's modest for a 3.5 A breaker, but if you're packing multiple units in a sealed enclosure, account for the heat rise.