Schneider Electric GV4LE03S6

Schneider GV4LE03S6 TeSys GV4 Motor Circuit Breaker, 3.5 A

MPN GV4LE03S6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4LE03S6, 3.5 A rated current, 120 kA breaking capacity at 240 V AC, 3-pole, magnetic-electronic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE03S6 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

GV4LE03S6 additional specifications
ParameterValue
Storage temperature-50...85 °C
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

The Schneider Electric GV4LE03S6 is a 3-pole motor circuit breaker from the TeSys GV4 series, rated for 3.5 A continuous current. That 3.5 A is the motor full-load current it protects — pair it with a contactor sized for the same motor FLA. The magnetic-electronic trip unit gives it a magnetic trip window of 21 to 49 A, so it handles inrush without nuisance tripping on a 0.55 kW motor at 400 V. Breaking capacity is the headline here: 120 kA Icu at 240 V AC, 100 kA at 415 V, and still 10 kA at 690 V. That means it can sit upstream of a fault with enough interrupting capacity to clear a bolted short without the upstream feeder breaker having to open — selectivity without a bigger frame. Rated for isolation per IEC 60947-1, so it doubles as a visible disconnect.

The GV4L frame takes a 27 mm connection pitch without spreaders, 35 mm with. That's a standard DIN-rail footprint — snaps onto the rail, no screws. The toggle control and lugs/ring terminals mean a panel builder can land 16 to 95 mm² cable at 9 N·m torque, or 1.5 to 10 mm² at 5 N·m. IP40 front-of-panel protection, IK07 impact rating — it's a panel-mount device, not a washdown unit. The grey RAL 7016 housing is the standard TeSys Deca colour. Operating altitude up to 5000 m means it's fine for high-altitude installations without derating.

MPN
GV4LE03S6