Schneider Electric GV4LE115N6

Schneider Electric GV4LE115N6 TeSys Deca Motor Circuit Break

MPN GV4LE115N6
Active

Schneider Electric, TeSys Deca series, GV4LE115N6 motor circuit breaker, 3P, 115 A In, 100 kA Icu at 240 V AC, 50/60 Hz.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE115N6 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

GV4LE115N6 additional specifications
ParameterValue
Storage temperature-50...85 °C
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles10000 cycles for AC-3 at 440 V In/2 5000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

It's a 3-pole unit with a toggle control, designed for motor protection in industrial control panels. The headline breaking capacity is 100 kA Icu at 220...240 V AC, dropping to 50 kA at 380...415 V AC and 15 kA at 525 V AC. That's enough SCCR headroom for most industrial service-entrance or sub-distribution boards fed by a transformer of moderate impedance. The magnetic trip is set at 480...1120 A, meaning it clears bolted faults fast while riding through normal motor inrush.

Motor power and application fit

The GV4LE115N6 covers a wide motor power band depending on the supply voltage: 37 kW at 400 V, 55 kW at 500 V, and up to 110 kW at 690 V. The trip unit is magnetic-electronic, so it provides both short-circuit and overload protection in a single device. For a 115 A motor circuit breaker, this is the range you'd expect for a 37–55 kW motor at common European voltages. Utilisation category is AC-3 per IEC 60947-4-1, which is the standard for squirrel-cage motors — starting, stopping, and occasional plugging. The electrical durability is 10,000 cycles at AC-3 at 440 V with half-rated current, and 5,000 cycles at full-rated current. Mechanical durability is 40,000 cycles. That's a solid service life for a motor branch circuit in a conveyor, pump, or fan application.

The breaker measures 155 mm high by 81 mm wide by 116 mm deep. The connection pitch is 27 mm without spreaders, expanding to 35 mm with spreaders — important to note when laying out the gland plate and busbar runs in a dense panel. IP40 protection means it's fine inside a clean enclosure but not for washdown areas. The IK07 impact rating handles accidental tool drops. Operating altitude goes to 5000 m, which covers most high-altitude installations without derating. Terminals accept lugs or ring terminals for cable from 1.5 to 95 mm², with tightening torques of 5 N.m for the smaller range and 9 N.m for the larger. That's a robust connection range — enough for the 115 A rating with standard copper cable.