Skip to main content
Schneider Electric GV4LE25S6

Schneider Electric GV4LE25S6 TeSys GV4 Motor Circuit Breaker

MPN GV4LE25S6
Active

Schneider Electric TeSys GV4 motor circuit breaker, 3-pole, 25 A rated current, magnetic-electronic trip, 120 kA breaking capacity at 240 V, IP40, current production.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE25S6 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C

All specifications

GV4LE25S6 additional specifications
ParameterValue
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 20000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

It is designed for motor protection, combining magnetic and electronic trip technology in a single device. Rated at 25 A continuous duty (In), it handles motor loads up to 7.5 kW at 400...415 V AC and up to 18.5 kW at 660...690 V AC, with a rated operational voltage (Ue) of 690 V AC and insulation voltage (Ui) of 800 V AC. The magnetic tripping window is set at 150...350 A, meaning it clears short-circuit faults fast while riding through normal motor inrush. Breaking capacity (Icu) reaches 120 kA at 240 V AC, 100 kA at 415 V, and 10 kA at 690 V, all per IEC 60947-2.

Electrical durability is 40,000 cycles at AC-3 with half rated current (In/2) and 20,000 cycles at full In at 440 V. That sets the service life expectation for a motor-starting application. Power dissipation per pole is 6.1 W, so total heat load in the enclosure is roughly 18.3 W at rated current. Factor that into your thermal budget — especially in a sealed, non-ventilated panel. Suitable for indoor panel mounting, not washdown environments. IK07 impact resistance handles routine panel knocks.

Compliance documentation includes EN/IEC 60947-4-1 and 60947-2 certification, fire resistance to 960 °C (IEC 60695-2-11), climatic withstand per IACS, and suitability for isolation per IEC 60947-1. That covers the main regulatory requirements for industrial control panels in most jurisdictions.

MPN