Skip to main content
Schneider Electric GV4LE50B6

Schneider Electric GV4LE50B6 TeSys GV4 Motor Circuit Breaker

MPN GV4LE50B6
Obsolete

Schneider Electric TeSys GV4 series, GV4LE50B6, motor circuit breaker, 3-pole, 50 A rated current, magnetic-electronic trip, 50 kA breaking capacity at 240 V.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE50B6 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C

All specifications

GV4LE50B6 additional specifications
ParameterValue
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles20000 cycles for AC-3 at 440 V In/2 10000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

The Schneider Electric GV4LE50B6 is a 3-pole motor circuit breaker from the TeSys GV4 series, rated at 50 A continuous and designed for motor protection under IEC 60947-4-1 and IEC 60947-2. The 50 A rating means it directly protects a motor drawing that full-load current — no external overload relay needed.

Breaking capacity — what it handles in a fault

Breaking capacity is 50 kA Icu at 240 V AC, dropping to 25 kA at 415 V and 10 kA at 500 V. At 400 V nominal, the 25 kA Icu covers most industrial distribution boards.

Motor power coverage — which motors it fits

The GV4LE50B6 covers a wide motor power band depending on line voltage: 11 kW at 400 V, 18.5 kW at 500 V, and up to 45 kW at 690 V. That spread means one part number serves motors across different supply voltages — useful for a plant with mixed-voltage zones or export machines.

Dimensions are 155 mm high, 81 mm wide, 116 mm deep — a compact 3-pole footprint that fits standard DIN-rail or panel-mount layouts. Operating altitude up to 5000 m, any mounting position.

Mechanical durability is 40,000 cycles; electrical durability is 20,000 cycles at AC-3, 440 V at half rated current, and 10,000 cycles at full rated current. Maximum operating rate is 25 cycles per hour — fine for a motor starting a few times per shift, not for high-speed jogging. Power dissipation is 6.1 W per pole, so three poles total 18.3 W of heat inside the enclosure — account for that in thermal calculations.

Certified to EN/IEC 60947-4-1 (motor starters) and EN/IEC 60947-2 (circuit breakers). Climatic withstand conforms to IACS for marine environments. Fire resistance at 960 °C per IEC 60695-2-11. Rated insulation voltage 800 V, operational voltage 690 V.

MPN
GV4LE50B6