Skip to main content
Schneider Electric LA9FG4G4F

LA9FG4G4F TeSys F Mechanical Interlock for 3 Vertical Contac

MPN LA9FG4G4F
Obsolete

Schneider Electric TeSys F, LA9FG4G4F, mechanical interlock for three vertical contactors, LC1F115...LC1F225 and CR1F150/CR1F185.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LA9FG4G4F specifications
ParameterValue
Main product or component typeMechanical interlock

Product details

The LA9FG4G4F is a mechanical interlock from the TeSys F range, designed to prevent simultaneous closure of three vertically mounted contactors or reversing contactors. It physically blocks the armature of one device from engaging while another is closed, which is critical for motor reversing circuits or any application where two contactors must never be energized at the same time. It interlocks bottom-position LC1F115 through LC1F150 3P or 4P contactors (and CR1F150 equivalents) with top-position LC1F185 through LC1F225 3P or 4P units (and CR1F185 equivalents), plus a middle position for the larger frame. Mounting is specified as three vertical, which is the standard orientation for a three-contactor reversing or star-delta group in a control panel. The mechanical linkage is a passive device — no wiring, no coil, just a bracket and rod assembly that transfers the blocking force between the contactor yokes.

It is classified under the 18402-WORLD SERVICE PARTS (CONTROL ACCESS) category, which typically means it is stocked as a serviceable accessory for installed TeSys F installations.

Integration Notes

The interlock mounts between the contactors on a DIN rail or backplate. The three vertical positions are fixed: the bottom position takes the smaller frame (115–150 A), the top and middle positions take the larger frame (185–225 A). Verify the frame size of each contactor before assembling — swapping positions will not align the mechanical linkage. No electrical connections are needed; the interlock is purely mechanical. It adds no power draw or heat to the panel. The assembly adds roughly the width of one additional contactor to the group, so account for that in the panel layout.

MPN
LA9FG4G4F