Skip to main content
Schneider Electric LC1F1504Q7

Schneider LC1F1504Q7 TeSys F Contactor, 250 A AC-1, 380 V Co

MPN LC1F1504Q7
Obsolete

Schneider Electric TeSys F series, LC1F1504Q7, 4-pole contactor, 250 A AC-1, 380 V AC 40-400 Hz coil, plate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F1504Q7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage380 V AC 40...400 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current250 A (at <40 °C) at <= 440 V AC-1
Breaking capacity1200 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-40 °C

All specifications

LC1F1504Q7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth171 mm
Width200.5 mm
Height170 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load
Operating time35 ms closing at Uc) 130 ms opening at Uc)
Operating temperature-40...60 °C
Permissible ambient air temperature around the device60...70 °C at Uc

Product details

The Schneider Electric LC1F1504Q7 is a TeSys F series 4-pole contactor with a 380 V AC 40-400 Hz control coil, rated for 250 A in AC-1 utilisation category — meaning it's built for switching resistive loads like heaters or furnaces, not motor starting. The 4 NO power pole configuration and 250 A continuous rating at 440 V make it a heavy-duty line contactor for panel builders working on ovens, kilns, or large resistive banks.

Heat dissipation runs 5.9 to 7.2 W total, so panel ventilation is minimal for a contactor this size. Control circuit is AC only, 380 V at 40-400 Hz, with operational limits of 0.85 to 1.1 Uc and drop-out between 0.2 and 0.55 Uc. Inrush power hits 770 VA at 20 °C, then hold-in drops to 8.1 VA — the coil draw matters for transformer sizing if you're feeding multiple contactors from a single control transformer. Closing time is 35 ms, opening 130 ms at rated voltage. Mechanical durability is rated at 10 million cycles, and the maximum operating rate is 2400 cycles per hour at 55 °C — that's one cycle every 1.5 seconds, fine for cyclic resistive loads but not for high-speed motor jogging. Ambient operating range is -40 to 60 °C, storage -60 to 80 °C, with no derating up to 3000 m altitude.

Mounting is plate-only — no DIN-rail clip on this frame size, so plan for a backplate or mounting plate with the 171 mm depth, 200.5 mm width, and 170 mm height. Power circuit connections accept bar (25 x 3 mm busbar), ring terminals up to 120 mm², or bolted connection. Control wiring uses screw clamp terminals accepting 1 to 4 mm² flexible or solid, with tightening torque of 1.2 N.m for control and 18 N.m for power. IP2X front face with shrouds per IEC 60529 and VDE 0106 — not washdown-rated, so keep it in a closed panel.

The LC1F1504Q7 complies with EN 60947-1, IEC 60947-1, JIS C8201-4-1, EN 60947-4-1, and IEC 60947-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Impulse withstand voltage is 8 kV, overvoltage category III. Protective treatment is TH (tropicalized) for humid environments. Associated fuse protection is 160 A aM or 250 A gG at <= 440 V.

MPN
LC1F1504Q7