Skip to main content
Schneider Electric LC1F2254E7

Schneider Electric LC1F2254E7 TeSys F Contactor, 315 A AC-1,

MPN LC1F2254E7
Obsolete

Schneider Electric TeSys F, LC1F2254E7, 4-pole contactor, 315 A AC-1 at ≤440 V, 48 V AC 40-400 Hz coil, plate mount, end-of-life.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F2254E7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage690 V AC 50/60 Hz
Coil voltage48 V AC 40...400 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current315 A (at <40 °C) at <= 440 V AC-1
Breaking capacity1800 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C

All specifications

LC1F2254E7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth181 mm
Width208.5 mm
Height197 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load
Operating time35 ms closing at Uc) 130 ms opening at Uc)
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The Schneider Electric LC1F2254E7 is a TeSys F 4-pole contactor rated for 315 A in AC-1 utilisation category (resistive loads) at ≤440 V, with a 48 V AC 40-400 Hz control coil. It carries IEC 60947-4-1 and EN 60947-4-1 approvals, meaning it meets the international standard for contactors and motor-starters — the core certification for panel builders and OEMs specifying this class of power switching.

The headline figure is 315 A rated operational current in AC-1 duty — that's the resistive load rating, not the motor-switching (AC-3) figure. The control coil draws 1070 VA inrush and 9.9 VA hold-in at 48 V AC, 40-400 Hz; the drop-out voltage range (0.2 to 0.55 Uc) means the contactor releases reliably when control voltage dips below about 26 V. Mechanical durability is 10 Mcycles, so it's built for high-cycle applications like conveyors or packaging lines where the contactor cycles thousands of times per hour (max 2400 cyc/h at 55 °C).

The manufacturer has marked the LC1F2254E7 as end-of-life (EOL). For BOM lines that require this exact code, procurement should plan for last-time-buy or surplus-channel sourcing. No production-status claim is made beyond the EOL designation.

The contactor is designed for plate mounting (not DIN rail). Dimensions are 208.5 mm wide, 197 mm high, 181 mm deep — a substantial footprint that requires panel space planning. Power circuit connections use bar, lug-ring, or bolted terminals accepting up to 185 mm² cable or 32 x 4 mm busbar; control circuit connections are screw-clamp terminals accepting 1 to 4 mm² flexible or solid wire. Tightening torque for the power circuit is 35 N.m, control circuit 1.2 N.m. The IP20 front-face protection (with shrouds) is standard for enclosed panels; no washdown rating.

MPN
LC1F2254E7