Skip to main content
Schneider Electric LC1F4004P7

Schneider TeSys F LC1F4004P7 Contactor, 500 A AC-1, 4 NO, EO

MPN LC1F4004P7
Obsolete

Schneider Electric TeSys F LC1F4004P7, 4-pole contactor, 500 A AC-1 at ≤440 V, 230 V AC coil, plate mount, end-of-life.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F4004P7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage230 V AC 40...400 Hz
Current500 A (at <40 °C) at <= 440 V AC AC-1
Breaking capacity3200 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-60...80 °C

All specifications

LC1F4004P7 additional specifications
ParameterValue
Depth219 mm
Width261 mm
Height206 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load
Operating time40...65 ms closing 100...170 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The Schneider Electric LC1F4004P7 is a 4-pole contactor from the TeSys F range, rated for 500 A in AC-1 utilisation category at ≤440 V — meaning it is built for switching resistive loads like heaters or furnaces, not motor starting. The 4 NO power pole composition gives you four normally-open main contacts that close when the 230 V AC coil pulls in.

Mounts on a plate — not DIN rail — so panel layout needs to account for the 261 mm width, 206 mm height, and 219 mm depth. Power connections are via bar (30 x 5 mm busbar cross-section) or ring-lug terminals up to 150 mm²; control wiring uses screw clamp terminals accepting 1…4 mm² flexible or solid. Tightening torque is 1.2 N·m on the control circuit and 35 N·m on the power circuit — that 35 N·m figure is a reminder to use a torque wrench on the main lugs, not a hand-tight guess.

Designed to IEC 60947-4-1 and EN 60947-4-1, the contactor standards for low-voltage switchgear. Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand voltage of 8 kV. The front face carries IP20 protection with shrouds fitted, conforming to IEC 60529 and VDE 0106.

MPN
LC1F4004P7