Skip to main content
Schneider Electric LC1G225LSEA

Schneider LC1G225LSEA TeSys Giga Contactor, 225 A, 200-500 V

MPN LC1G225LSEA
Active

Schneider Electric TeSys Giga LC1G225LSEA, 3-pole contactor, 225 A AC-3e, coil 200-500 V AC/DC, dark grey.

$1,430.00 – $1,497.59 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1G225LSEA key specifications
ParameterValue
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage200...500 V AC 50/60 Hz 200...500 V DC
Insulation voltage ui1000 V
Current330 A (at 225 A (at <140 °F (60 °C)) at <= 440 V AC-3
Breaking capacity2050 A at 440 V
Utilization categoryAC-1 AC-3 AC-3e AC-4 AC-5 a AC-5b AC-6 a AC-6b AC-8b AC-8 a DC-1 DC-3 DC-5
Terminal pitch1.4 in (35 mm)
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-25 °C

All specifications

LC1G225LSEA additional specifications
ParameterValue
Storage temperature-76...176 °F (-60...80 °C)
ColorDark grey
Depth7.6 in (193 mm)
Width4.3 in (108 mm)
Height10.04 in (255 mm)
Mechanical life cycles8 Mcycles
ApplicationPower switching Motor control
Operating time40...70 ms closing 15...50 ms opening
Operating temperature-13...140 °F (-25...60 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C) at Uc

Product details

What this contactor is for

The LC1G225LSEA is a 3-pole TeSys Giga contactor from Schneider. Coil accepts 200-500 V AC or DC, rated for AC-3e duty at 110 kW on 400 V.

What the numbers actually mean for the BOM

Mechanical durability is 8 Mcycles — that's not a lab number; that's a decade of full-speed production cycling. The power dissipation per pole runs 20 W in AC-1 and 8 W in AC-3, so thermal management is straightforward: standard panel ventilation will do. The contactor is also TH-treated for humidity resistance, which matters if the panel breathes ambient air. Associated fuse recommendations are given for aM, gG, and UL Type J — the 250 A aM and 200 A aM ratings let you size the short-circuit protection without digging into coordination software. The 400 A gG and Type J cover the full-load and backup roles.

Wiring and mounting in the real world

Mechanical vibration tolerance is 2 gn open and 4 gn closed (5-300 Hz), shock 15 gn closed — it'll stay put on a machine tool or pump skid.

MPN