Schneider Electric LC1K06016M7

Schneider LC1K06016M7 TeSys K Contactor, 3P, 6A AC-3, 220-23

MPN LC1K06016M7
Obsolete

Schneider Electric TeSys K contactor, LC1K06016M7, 3P, AC-3/AC-3e 6 A at 440 V, 1 NC aux, 220…230 V AC standard coil, obsolete status.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1K06016M7 specifications
ParameterValue
Main product or component typeContactor
Utilization categoryAC-3 AC-3e AC-4
Depth57 mm
Width45 mm
Height58 mm
Electrical life cycles1.3 Mcycles 6 A AC-3 at Ue 1.3 Mcycles 6 A AC-3e at Ue 0.05 Mcycles 36 A AC-4 at Ue <= 440 V
Mechanical life cycles10 Mcycles
ApplicationMotor control
Operating time10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing

Product details

The Schneider Electric LC1K06016M7 is a TeSys K three-pole contactor rated for motor control duty, with a 6 A operational current in AC-3 and AC-3e utilisation categories at 440 V. It carries a 220…230 V AC standard coil without a built-in suppressor module, and includes one normally-closed instantaneous auxiliary contact. The contactor is designed for control applications in motor circuits, switching loads such as pumps, conveyors, and fans up to its rated capacity.

The AC-3 rating of 6 A at 440 V governs motor switching — this is the current the contactor can make and break under inrush from a squirrel-cage motor starting. The AC-3e rating extends this to energy-efficient motors with higher inrush. AC-4 is also listed for plugging and inching duty, but at a reduced electrical durability of 0.05 Mcycles at 36 A. The 1.3 Mcycles electrical endurance at 6 A AC-3 is the figure a panel builder uses to estimate service life under normal motor starts. The 10 Mcycles mechanical durability sets the upper bound without electrical load.

This part is marked obsolete by the manufacturer.

Terminals accept lugs or ring terminals with a 7 mm outer diameter. The coil draws 30 VA inrush and 4.5 VA hold-in at 20 °C, dissipating 1.3 W. The non-overlap distance of 0.5 mm between NO and NC contacts ensures break-before-make timing. Operating altitude is 2000 m without derating; shock and vibration ratings are listed per IEC 60068-2-27 and IEC 60068-2-6 for both open and closed contactor states.

MPN
LC1K06016M7