Schneider Electric LC1K09106L7

TeSys K LC1K09106L7 Contactor, 3P, 9A AC-3, 200-208V AC Coil

MPN LC1K09106L7
Active

Schneider Electric TeSys K contactor, LC1K09106L7, 3-pole, 9 A AC-3/AC-3e at ≤440 V, 1 NO auxiliary contact, 200…208 V AC coil, active production.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1K09106L7 specifications
ParameterValue
Main product or component typeContactor
Utilization categoryAC-3 AC-3e AC-1 AC-4
Depth57 mm
Width45 mm
Height58 mm
Electrical life cycles1.3 Mcycles 9 A AC-3 at Ue 1.3 Mcycles 9 A AC-3e at Ue 0.16 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 54 A AC-4 at Ue <= 440 V
Mechanical life cycles10 Mcycles
ApplicationResistive load Motor control
Operating time10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing

Product details

The LC1K09106L7 is a TeSys K 3-pole contactor rated 9 A in AC-3 and AC-3e utilisation categories at ≤440 V, with a 200…208 V AC coil. Rated operational voltage covers power circuit use up to 440 V; the signalling circuit handles frequencies up to 400 Hz. Minimum switching capability is 5 mA at 17 V for signalling, so it can reliably switch PLC-level signals without contact wetting issues.

The AC-3 rating of 9 A is the motor-switching current — that's the figure that governs real-world fit for standard squirrel-cage motors. Electrical durability at that rating is 1.3 million cycles; at AC-1 resistive load (20 A) it drops to 160,000 cycles, and at AC-4 (54 A inrush) to 20,000 cycles. Mechanical durability is 10 million cycles, so the contactor will outlast the machine's service life in most panel applications. Coil hold-in power is 4.5 VA at 20 °C; inrush is 30 VA. The coil has no built-in suppressor module, so you'll need to add an RC snubber or free-wheeling diode across the coil if driving it from a PLC output or solid-state relay. Operational voltage limits: coil picks up at 0.8 × Uc and drops out at 0.2 × Uc (below 50 °C). That gives a wide hold-in range — useful if your control transformer sags under load. Operating time is 10…20 ms for both closing and opening, consistent with standard IEC contactor response.

Terminals accept ring lugs with a 7 mm outer diameter. The 3 NO power poles and 1 NO auxiliary contact are fixed; no add-on contact blocks are needed for basic motor starter wiring.