Schneider Electric LC2K1601U7

TeSys K LC2K1601U7 reversing contactor, 3P, 16 A AC-3, 230-2

MPN LC2K1601U7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NC, 230-240 V AC coil, IP20, 57 mm depth.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC2K1601U7 specifications
ParameterValue
Main product or component typeReversing contactor
Utilization categoryAC-3 AC-4
IP ratingIP20
Temp storage max80 °C
Temp storage min-50 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-50...80 °C
Depth57 mm
Width90 mm
Height58 mm
ApplicationMotor control
Operating temperature-25...50 °C

Product details

The 3-pole configuration with 3 NO power poles and 1 NC auxiliary contact covers the basic reversing scheme — the NC provides electrical interlocking to prevent both contactors pulling in simultaneously.

This part is classified as Obsolete by the manufacturer. No official successor order code is listed. If you are evaluating a replacement for a new design, the TeSys K family has been superseded by the TeSys Deca range; verify footprint and coil voltage compatibility before substituting.

AC-4 rating covers plugging and inching, which is harder on the contacts. Rated operational voltage of 690 V AC on the power circuit; signalling circuit isolation rated at 10 MOhm. Flame retardance to UL 94 V1 and NF F 16-101/102 means the housing meets rail and general industry fire-safety standards. Mechanical robustness tested to 10-15 Gn shock and 4 Gn vibration (contactor closed) per IEC 60068-2-27 and IEC 60068-2-6 — suitable for applications with moderate vibration like conveyor drives or pump skids. Operating altitude of 2000 m without derating covers most installations; above that, dielectric withstand and thermal dissipation need to be checked.

Integration notes

The preassembled reversing busbar saves panel wiring time but locks the mechanical interlock arrangement — verify the busbar orientation matches your enclosure layout before mounting. Coil is 230-240 V AC; confirm control transformer sizing and that the coil draw does not exceed the PLC output or relay rating driving it.