Skip to main content
Schneider Electric LG1K065Q704

TeSys LG1K065Q704 Enclosed DOL Starter, 0.4-0.63 A, Obsolete

MPN LG1K065Q704
Active

Schneider Electric TeSys LG enclosed DOL starter, LG1K065Q704, 0.4-0.63 A thermal protection, 380/400 V AC coil, IP55, obsolete.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LG1K065Q704 specifications
ParameterValue
Main product or component typeEnclosed DOL starter
Coil voltage380/400 V AC 50/60 Hz
Utilization categoryAC-3
IP ratingIP55
Depth165 mm
Width175 mm
Height165 mm
MaterialPolycarbonate
ApplicationSafety
Thermal protection adjustment range0.4–0.63 A

Product details

The Schneider Electric TeSys LG1K065Q704 is an enclosed DOL (direct-on-line) starter combining a contactor, switch-disconnector, and circuit-breaker in one IP55 polycarbonate enclosure. It is rated for AC-3 motor duty at 0.18 kW on 400/415 V AC supplies, with a thermal protection adjustment range of 0.4 to 0.63 A and a 380/400 V AC control coil. The IP55 rating means the enclosure is dust-protected and withstands water jets from any direction — suitable for washdown areas in food processing or light industrial environments where hose-down cleaning is routine. The IK07 impact rating confirms it resists 2 J impacts, enough for accidental tool drops in a panel bay.

Integration notes for panel builders

Cable entries include four Pg 13 and two Pg 16 knockouts on both top and bottom faces, giving flexibility for top-entry or bottom-entry wiring in a panel gland plate. The polycarbonate enclosure is lightweight and corrosion-resistant, but the IP55 seal means gland nuts must be properly torqued to maintain the rating. The front panel carries a white push-button start, black push-button stop, and a red rotary emergency stop handle — all pre-wired to the internal contactor and disconnect. The thermal overload adjustment range of 0.4 to 0.63 A is set via a dial inside the enclosure. For a 0.18 kW motor at 400 V (full-load current typically around 0.5 A), set the dial to the motor nameplate FLA. The unit complies with IEC 60204-1 for electrical equipment of machines, so it meets the safety standard for machine control panels.

MPN
LG1K065Q704