Skip to main content
Schneider Electric LP1D40008GD

Schneider LP1D40008GD TeSys Deca Contactor, 4-pole, 125 VDC coil, 40 A AC-3

MPN LP1D40008GD
Active

Schneider Electric TeSys Deca LP1D40008GD contactor, order code LP1D40008GD, 4 poles, 125 V DC coil, 40 A AC-3 / 60 A AC-1, 5.4 W sealed power, IP20, DIN-rail or plate mount.

$489.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LP1D40008GD key specifications
ParameterValue
Control circuit typeDC DC standard
Main product or component typeContactor
VoltagePower circuit: 1000 V AC 25...400 Hz
Coil voltage125 V DC
Current60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
Breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
Utilization categoryAC-1
IP ratingIP20
Temp operating max60 °C
Temp operating min-40 °C
Pollution degree3
Depth7.2 in (182 mm)

All specifications

LP1D40008GD additional specifications
ParameterValue
Width3.3 in (85 mm)
Height5 in (127 mm)
Electrical life cycles1.4 Mcycles 60 A AC-1 <= 440 V
Mechanical life cycles10 Mcycles
ApplicationResistive load
Fire behaviorV1 conforming to UL 94
Time constant75 ms
Operating time4...19 ms opening 12...26 ms closing
Permissible ambient air temperature around the device-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating

Product details

Overview

The LP1D40008GD is a Schneider Electric TeSys Deca 4-pole contactor, rated 40 A in AC-3 (inductive motor duty) and 60 A in AC-1 (resistive load). It carries a 125 V DC coil with a built-in bidirectional peak limiting diode suppressor, drawing 5.4 W sealed power.

The LP1D40008GD uses a DC standard control circuit with a built-in bidirectional peak limiting diode suppressor across the coil, which absorbs the inductive kickback on de-energization. The coil operates at 125 V DC nominal with a resistance of 1562 ohms and a time constant of 0.075 s, producing an operating time of 4 ms. The 4-pole configuration allows switching of three-phase motor loads plus a neutral or auxiliary circuit in a single device. The power circuit carries a breaking capacity of 800 A at 440 V per IEC 60947, and the average impedance is 1.5 mOhm at 60 A 50 Hz, keeping heat dissipation low. Auxiliary contacts are built in as 1NO-1NC, sufficient for basic feedback or interlocking without an add-on block. The contactor is rated for mechanical robustness: 8 Gn shock when open, 10 Gn when closed, and vibration resistance of 2 Gn at 5-300 Hz.

Applications

This 4-pole contactor is suited for motor starting and switching of resistive loads in industrial machinery, HVAC systems, pump and compressor panels, and conveyor lines. The 125 V DC coil is common in DC control systems found in battery-backed or solar-powered installations, and in older DC relay logic panels. The AC-1 rating of 60 A supports resistive loads. The AC-3 rating of 40 A covers induction motors.

Within the TeSys Deca range, the LP1D40008GD sits as a 4-pole DC-coil variant for applications requiring a 125 V DC control voltage. It is specified by panel builders and OEMs who need a compact, high-duty contactor with UL/CSA/IEC certifications for global machine export. The 4-pole format is less common than 3-pole in motor starting but is preferred for two-speed motors, star-delta transitions with a separate neutral, or resistive loads where a fourth pole switches a control circuit.

MPN
LP1D40008GD