Schneider Electric LP1K1210ED

TeSys K LP1K1210ED Contactor, 12A, 48V DC Coil, Obsolete

MPN LP1K1210ED
Obsolete

Schneider Electric TeSys K LP1K1210ED, 3-pole contactor, 12 A at 440 V AC-3/AC-3e, 48 V DC coil, 1 NO auxiliary contact, screw clamp terminals.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LP1K1210ED specifications
ParameterValue
Main product or component typeContactor
Utilization categoryAC-3 AC-3e AC-1 AC-4
IP ratingIP2X
Temp storage max80 °C
Temp storage min-50 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-50...80 °C
Depth57 mm
Width45 mm
Height58 mm
Electrical life cycles1.3 Mcycles 12 A AC-3 at Ue 1.3 Mcycles 12 A AC-3e at Ue 0.3 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Mechanical life cycles10 Mcycles
ApplicationResistive load, Motor control
Operating temperature-25...50 °C

Product details

The Schneider Electric LP1K1210ED is a 3-pole contactor from the TeSys K series, rated 12 A in AC-3/AC-3e duty at 440 V, with a 48 V DC coil and one normally open auxiliary contact.

The AC-3e rating (12 A) extends this to energy-efficient motors with higher inrush. For resistive loads (AC-1), the contactor handles 20 A. The mechanical durability of 10 Mcycles and electrical durability of 1.3 Mcycles at AC-3 mean this contactor is built for moderate-cycle applications like conveyors or pumps, not high-speed indexing. The 48 V DC coil draws 3 W inrush and hold-in power at 20 °C, with an operating range of 0.8 to 1.15 times the control voltage (Uc). Drop-out occurs at ≥ 0.10 Uc below 50 °C — important for control circuit design where undervoltage release is needed. The coil has no built-in suppressor module, so an external flyback diode or RC snubber should be added to protect the DC control circuit. The contactor carries a B10d of 1,369,863 cycles at nominal load per EN/ISO 13849-1, making it suitable for safety-related circuits where the contactor is part of a monitored safety function. The minimum switching capability of 5 mA at 17 V ensures reliable signalling even with low-energy control signals.

Sourcing Reality: Obsolete Part

This part is classified as obsolete by the manufacturer. For a BOM line or installed base that requires this exact code, sourcing is through surplus or broker channels.

Integration Notes

Tightening torque is 0.8 to 1.3 N·m. IP2X protection means it is not suitable for washdown or outdoor use without an enclosure.

MPN
LP1K1210ED