Skip to main content
Schneider Electric LUCAX6BLTQ

Schneider LUCAX6BLTQ TeSys U Standard Control Unit, 24 V DC

MPN LUCAX6BLTQ
Obsolete

Schneider Electric TeSys U standard control unit, LUCAX6BLTQ, 24 V DC control voltage, 690 V AC rated operational voltage, 0.09 kW at 400...440 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LUCAX6BLTQ specifications
ParameterValue
Load type3-phase motor - cooling: self-cooled
Main product or component typeStandard control unit
Voltage690 V AC
Coil voltage24 V DC
Insulation voltage ui690 V conforming to IEC 60947-6-2 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
Utilization categoryAC-41 AC-44 AC-43
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Depth60 mm
Width45 mm
Height66 mm
ApplicationMotor control Motor protection
Fixing modePlug-in (front face)
Operating time35 ms opening with LUB12 for control circuit 35 ms opening with LUB32 for control circuit 35 ms opening with LUB38 for control circuit 70 ms closing with LUB12 for control circuit 70 ms closing with LUB32 for control circuit 70 ms closing with LUB38 for control circuit
Operating temperature-25...70 °C

Product details

What the LUCAX6BLTQ does in a motor starter

The Schneider Electric LUCAX6BLTQ is a standard control unit from the TeSys U range, designed for basic motor protection and control in a 3-phase motor starter assembly. It handles overload and short-circuit protection, earth fault detection, and phase failure sensitivity, with a manual reset. The unit is rated for 0.09 kW at 400...440 V AC 50/60 Hz, so it's sized for small motor loads like fans or pumps on a conveyor line.

Control voltage is 24 V DC, with an operating range of 20...27 V DC and a drop-out threshold at 14.5 V DC. That means the coil holds reliably at 24 V nominal but drops out cleanly below 14.5 V, preventing chatter on a sagging supply. Typical current consumption is 60 mA sealed with a LUB12 base, spiking to 130 mA during closing — the control transformer or DC supply needs to handle that inrush. Rated operational voltage is 690 V AC, with insulation rated at 690 V per IEC 60947-6-2 and 600 V per UL 60947-4-1. The utilisation categories are AC-41, AC-44, and AC-43 — these cover motor switching with moderate to high inrush, so the unit is suited for direct-on-line starting of induction motors within its power band. The magnetic short-circuit release trips at 14.2 x Ir ±20%. Thermal overload protection follows Class 10 characteristics, temperature-compensated from -25 to 70 °C, matching IEC 60947-6-2 and UL 508 requirements.

The LUCAX6BLTQ plugs into the front face of a TeSys U base (LUB12, LUB32, or LUB38), occupying 45 mm width on the DIN rail. IP20 on the front panel and wired terminals keeps it safe for enclosed panel mounting; IP40 outside the connection zone. Heat dissipation runs 2 W with a LUB12 base, 3 W with LUB32 or LUB38 — factor that into the panel thermal budget.

MPN