Skip to main content
Schneider Electric LUCB05BLTQ

Schneider LUCB05BLTQ TeSys U Advanced Control Unit

MPN LUCB05BLTQ
Obsolete

Schneider Electric TeSys U advanced control unit, LUCB05BLTQ, 1.5 kW at 400 V AC, 24 V DC control circuit, manual reset, IP20 front panel.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LUCB05BLTQ specifications
ParameterValue
Load type3-phase motor - cooling: self-cooled
Main product or component typeAdvanced control unit
Voltage690 V AC
Coil voltage24 V DC
Insulation voltage ui690 V conforming to IEC 60947-6-2 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
Utilization categoryAC-41 AC-44 AC-43
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Depth60 mm
Width45 mm
Height66 mm
ApplicationMotor control Motor protection
Fixing modePlug-in (front face)
Operating time35 ms opening with LUB12 for control circuit 35 ms opening with LUB32 for control circuit 35 ms opening with LUB38 for control circuit 70 ms closing with LUB12 for control circuit 70 ms closing with LUB32 for control circuit 70 ms closing with LUB38 for control circuit
Operating temperature-25...70 °C

Product details

Rated for 1.5 kW at 400...440 V AC 50/60 Hz, it steps up to 2.2 kW at 500 V AC and 3 kW at 690 V AC, covering a useful spread of three-phase motor loads in European and North American voltage systems. The 24 V DC control circuit draws 130 mA peak on closing with the LUB12 interface, settling to 60 mA sealed — numbers that matter when sizing the control transformer or DC supply for a multi-starter panel. Utilisation categories AC-41, AC-43, and AC-44 mean it handles resistive, motor, and lightly inductive loads respectively, with the AC-44 rating confirming it can switch motor loads up to its rated power without derating.

Protection functions and trip behaviour

This unit provides earth fault protection, protection against phase failure and phase imbalance, and overload and short-circuit protection, all with a manual reset that requires a physical button push after a trip. The thermal overload curve is Class 10, frequency-compensated 40...60 Hz and temperature-compensated -25...70 °C per IEC 60947-6-2 and UL 508 — meaning it tracks motor heating closely enough to protect a standard squirrel-cage motor without nuisance tripping on a normal start. Tripping threshold is 14.2 x Ir +/- 20 %. Phase failure sensitivity is built in — if one phase drops, the unit trips within the operating time of 35 ms opening (with LUB12, LUB32, or LUB38 control circuit interfaces).

Dimensions are 45 mm wide, 66 mm high, and 60 mm deep, fitting the standard TeSys U footprint that rows up neatly on DIN rail or a backplate. Rated insulation voltage is 690 V per IEC 60947-6-2 and 600 V per UL 60947-4-1 and CSA C22.2 No 60947-4-1, with safe separation of 400 V SELV between control/auxiliary circuits and the main circuit. Standards compliance includes EN/IEC 60947-6-2, IEC 60947-6-2, UL 60947-4-1 with phase barrier, and CSA C22.2 No 60947-4-1 with phase barrier — covering the main global certification schemes for motor starters.

If you're holding a legacy BOM that calls out an older TeSys U control unit, the LUCB05BLTQ is the direct functional equivalent for the 1.5 kW / 400 V class — no adapter or wiring change needed.

MPN
LUCB05BLTQ