Skip to main content
Schneider Electric LUCL05B

Schneider TeSys Ultra LUCL05B Magnetic Control Unit

MPN LUCL05B
Active

Schneider Electric TeSys Ultra LUCL05B magnetic control unit, 1.5 kW at 400 V, 24 V AC coil, plug-in front face, manual reset with short-circuit protection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LUCL05B specifications
ParameterValue
Load type3-phase motor - cooling: self-cooled
Main product or component typeMagnetic control unit
Voltage690 V AC
Coil voltage24 V AC
Insulation voltage ui690 V conforming to IEC 60947-6-2 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
Utilization categoryAC-41 AC-44 AC-43
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Depth60 mm
Width45 mm
Height66 mm
ApplicationMotor control Motor protection
Fixing modePlug-in (front face)
Operating time35 ms opening with LUB12 for control circuit 35 ms opening with LUB32 for control circuit 35 ms opening with LUB38 for control circuit 70 ms closing with LUB12 for control circuit 70 ms closing with LUB32 for control circuit 70 ms closing with LUB38 for control circuit
Operating temperature-25...70 °C

Product details

The Schneider Electric TeSys Ultra LUCL05B is a magnetic control unit — a compact, plug-in device that combines motor control and protection in a single 45 mm wide package. It is designed for 3-phase motor circuits, rated at 1.5 kW at 400...440 V AC, 2.2 kW at 500 V AC, and 3 kW at 690 V AC, all at 50/60 Hz. The 24 V AC control coil draws 140 mA inrush (220 mA with larger control modules) and settles to 70–90 mA sealed. The unit provides manual reset and short-circuit protection, with a tripping threshold of 14.2 x Ir ± 20%. It is specifically intended for protecting variable-speed drives or soft-start/soft-stop units, not just plain across-the-line starting. The utilisation categories — AC-41, AC-44, AC-43 — cover resistive, motor, and mixed loads, so it fits a range of downstream equipment.

The 14.2 x Ir tripping threshold means the unit allows a high inrush — typical for a motor starting — before it trips on a short-circuit. That is a deliberate design for motor circuits, not a general-purpose breaker characteristic. The 35 ms opening time (with any of the LUB12/32/38 control modules) means it clears a fault fast enough to limit let-through energy to downstream components. The SELV separation of 400 V between control/auxiliary and main circuits means the 24 V control loop is safely isolated from the power circuit — important for PLC or safety-relay interfaces. The TH protective treatment per IEC 60068 adds some humidity resistance for non-condensing environments.

The 45 x 66 x 60 mm footprint is compact enough for dense layouts. Heat dissipation is 2 W with the LUB12 control module, 3 W with LUB32 or LUB38 — negligible for most enclosures but worth noting if you are packing many units in a sealed cabinet.

The LUCL05B is certified to EN/IEC 60947-6-2, UL 60947-4-1, and CSA C22.2 No 60947-4-1 (with phase barrier). That covers the main global markets: IEC for Europe/Asia, UL for North America, CSA for Canada. The shock and vibration ratings — 10 gn open / 15 gn closed, and 2–4 gn at 5–300 Hz — confirm it holds up in machinery with moderate mechanical stress.

MPN
LUCL05B