Schneider Electric LUCL38FU

Schneider Electric LUCL38FU TeSys Ultra Magnetic Control Uni

MPN LUCL38FU
Active

Schneider Electric TeSys Ultra magnetic control unit, LUCL38FU, AC-43 utilization category, 18.5 kW at 400 V AC, plug-in front face, IP20 front panel.

$71.29 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LUCL38FU specifications
ParameterValue
Main product or component typeMagnetic control unit
Voltage690 V AC
Coil voltage110...240 V AC 110...220 V DC
Utilization categoryAC-43
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Depth60 mm
Width45 mm
Height66 mm
ApplicationMotor control Motor protection
Fixing modePlug-in (front face)
Operating temperature-25...70 °C

Product details

It is specifically listed for protecting variable-speed drives and soft-start units, not just across-the-line starting. Rated in utilization category AC-43, it handles 18.5 kW at 400…440 V AC, 18.5 kW at 500 V, and 22 kW at 690 V AC — the AC-43 rating means it is tested for the higher switching frequency and current stresses typical of drive-fed motors, where the waveform is not a clean sine wave.

Control circuit voltage is 110…240 V AC or 110…220 V DC, with a drop-out threshold of 55 V for either supply. Closing current peaks at 280 mA; sealed holding current drops to 25 mA rms — the coil draw is low enough that a standard PLC relay output can drive it, but verify the inrush if the output is a solid-state relay with a minimum load specification. The tripping threshold is 14.2 x Ir ±20 % — this is a magnetic-only instantaneous trip, not a thermal overload. It clears a bolted fault fast but provides no overload protection; that is why it pairs with a separate overload relay or the drive's own thermal model. IP20 on the front panel and wired terminals, IP40 on the front panel outside the connection zone.

Compliant with EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1 (with phase barrier), and CSA C22.2 No 60947-4-1 (with phase barrier). Safe separation between control/auxiliary circuits and the main circuit is maintained at 400 V SELV.

Mounts via plug-in front face — it clips onto a compatible TeSys Ultra base or directly onto the contactor assembly. Dimensions are 45 mm wide, 66 mm high, 60 mm deep. Operating time is 35 ms opening and 50 ms closing when paired with a LUB38 control unit.

MPN
LUCL38FU