Schneider Electric LV839071 MasterPact MTZ2, 1600A, 200kA Ic

MPN LV839071
Obsolete

Schneider Electric MasterPact MTZ2, LV839071, 3-pole drawout circuit breaker, 1600 A rated, breaking capacity, 200 kA Icu at 508 VAC 60 Hz, ANSI C37.50.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839071 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch4.5 in (115 mm)
Depth16.8 in (426.8 mm)
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Electrical life cycles2800 cycles ANSI C37.50
Mechanical life cycles12500 cycles ANSI C37.50
ApplicationProtection
Safety category200 kA Icu 254 V AC 60 Hz ANSI C37.50 200 kA Icu 508 V AC 60 Hz ANSI C37.50 130 kA Icu 635 V AC 60 Hz ANSI C37.50 200 kA Icu 254 V AC 50 Hz ANSI C37.50 150 kA Icu 508 V AC 50 Hz ANSI C37.50 100 kA Icu 635 V AC 50 Hz ANSI C37.50

Product details

The LV839071 is a MasterPact MTZ2 drawout circuit breaker rated 1600 A continuous at 40 °C, 3-pole, with an breaking capacity code. What sets this frame apart is the interrupting performance: 200 kA Icu at 254 V and 508 V AC 60 Hz per ANSI C37.50, and still 130 kA at 635 V AC 60 Hz. On 50 Hz systems the numbers drop slightly — 200 kA at 254 V, 150 kA at 508 V, 100 kA at 635 V — but that is still a very high fault-interruption capability for a 1600 A frame. The 30 kA short-time withstand (Icw) for 0.5 s means it coordinates well downstream; you can hold through a delayed trip without the main taking a hit. Drawout mounting means the breaker chassis stays wired to the bus while the moving portion racks out for maintenance or replacement — no need to kill the entire switchgear section for a swap. The 4.5 in (115 mm) connection pitch matches standard ANSI bus spacing, so it fits existing drawout cradle layouts without re-drilling the backplane. Mechanical durability is rated at 12,500 cycles, electrical endurance at 2,800 cycles under ANSI C37.50. For a 1600 A frame that is solid — you are looking at years of normal switching before contact inspection, assuming typical industrial duty cycles.

Protection and coordination specifics

Integral instantaneous protection is set at 49.5 to 55.5 kA — that is the magnetic-only trip range for bolted faults. Below that threshold, the electronic trip unit handles time-current curves. Maximum breaking time is 9 ms, closing response max 70 ms. These numbers matter for arc-flash incident energy calculations: faster clearing means lower let-through energy at the arcing fault level. Rated breaking and making capacity is 55 kA — this is the value for the standard duty cycle (O-3min-CO). The higher Icu numbers are the ultimate breaking capacity, one-shot capability. In practice, for selective coordination studies, use the Icw (30 kA / 0.5 s) as the withstand rating for downstream devices.