Schneider Electric LV839143

Schneider LV839143 MasterPact MTZ2 2500A 3P Drawout Circuit

MPN LV839143
Active

Schneider Electric MasterPact MTZ2 series, LV839143, UL 489 circuit breaker, 2500 A rated, 3-pole, drawout mount, H breaking capacity, 600 VAC, without Micrologic trip unit, with ArcBlok.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839143 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch4.5 in (115 mm)
Depth16.8 in (426.8 mm)
Width17.5 in (444.3 mm)
Height17.3 in (438.8 mm)
Electrical life cycles2800 cycles ANSI C37.50
Mechanical life cycles12500 cycles ANSI C37.50
ApplicationProtection
Safety category100 kA Icu 240 V AC 50/60 Hz UL 489 100 kA Icu 480 V AC 50/60 Hz UL 489 85 kA Icu 600 V AC 50/60 Hz UL 489

Product details

The LV839143 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, UL 489 listed, rated 2500 A continuous at 104 °F (40 °C) on a 600 VAC network, 50/60 Hz. Three-pole, H breaking capacity code — meaning 100 kA Icu at 240 VAC, 100 kA Icu at 480 VAC, and 85 kA Icu at 600 VAC per UL 489. This is the frame without a Micrologic trip unit; the ArcBlok arc-extinction system is integral. Drawout mounting on base plate rails (connection pitch 115 mm) means the breaker slides into a fixed cradle — the cassette stays wired while the breaker is racked out for isolation or swap. Panel builders spec this for main or tie positions where service continuity matters: rack the breaker to test/disconnect position without pulling the bus.

Breaking performance and coordination

Rated breaking and making capacity is 90 kA. Short-time withstand (Icw) is 65 kA for 0.5 s per UL 489 — that is the current the breaker can carry closed during a delayed trip, critical for selective coordination downstream. Integral instantaneous protection triggers between 135 and 165 kA; maximum breaking time is 25 to 30 ms, closing response within 70 ms. Mechanical durability is 12,500 cycles, electrical durability 2,800 cycles per ANSI C37.50. For a main breaker at 2500 A, that electrical endurance covers years of normal switching; the mechanical figure matters for racking and test operations.

Product status is Active per Schneider's current lifecycle record. This is not a phase-out or last-time-buy line — the MasterPact MTZ2 series is the current-generation UL 489 platform for high-current distribution.

Physical integration into the switchboard

Dimensions: width 17.5 in (444.3 mm), height 17.3 in (438.8 mm), depth 16.8 in (426.8 mm). The drawout cradle adds depth behind the mounting plate; verify the enclosure depth against the racked-in dimension plus clearance for the arc-chamber exhaust. Base plate rails support the assembly — no DIN-rail mounting on this class of breaker.

MPN
LV839143