LV839307 MasterPact MTZ3 4000A 3P Drawout Circuit Breaker

MPN LV839307
Active

Schneider Electric MasterPact MTZ3, LV839307, 3-pole drawout air circuit breaker, 4000 A rated, H2 breaking capacity (85 kA Icu at 508 VAC), without Micrologic trip unit, with ArcBlok.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839307 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch9.06 in (230 mm)
Depth16.8 in (426.8 mm)
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Electrical life cycles1000 cycles ANSI C37.50
Mechanical life cycles5000 cycles ANSI C37.50
ApplicationProtection
Safety category85 kA Icu 254 V AC 50/60 Hz ANSI C37.50 85 kA Icu 508 V AC 50/60 Hz ANSI C37.50 85 kA Icu 635 V AC 50/60 Hz ANSI C37.50

Product details

What you're specifying

The LV839307 is a MasterPact MTZ3 drawout air circuit breaker — 3-pole, 4000 A continuous rating at 40 °C, with H2 breaking capacity delivering 85 kA Icu at 508 VAC (also 85 kA at 254 VAC and 635 VAC per ANSI C37.50). This is the frame and mechanism only: it ships without a Micrologic trip unit, so you'll need to order the protection relay separately. The ArcBlok arc-extinction chamber is integral. Drawout mounting means this breaker slides into a cradle — no hard wiring for the main power connections during swap-out. Rated short-time withstand (Icw) is 85 kA for 0.5 s, which gives you selectivity headroom downstream. Mechanical durability is 5000 cycles; electrical durability 1000 cycles per ANSI C37.50.

Breaking capacity — what it means for coordination

The H2 code tells you the interrupting rating: 85 kA Icu at 254 V, 508 V, and 635 V AC. That's a flat 85 kA across the full ANSI voltage range, not a derated curve. For a 4000 A main breaker feeding a switchboard, that SCCR covers most industrial service-entrance and distribution applications without cascading upstream. Maximum breaking time is 25 to 30 ms; maximum closing response time is 70 ms. The 85 kA Icw for 0.5 s supports delayed tripping for selective coordination with downstream feeders — you can let a fault ride through on the feeder breaker without pulling the main.

The drawout chassis measures 31.07 in wide by 18.8 in high by 16.8 in deep, with a connection pitch of 9.06 in (230 mm) between phase centers. Mounting is on base plate rails — this is a floor-mount switchgear frame, not a DIN-rail clip. Verify your cell opening and bus bar spacing before committing the cutout.