Schneider Electric LV839316

Schneider Electric LV839316 MasterPact MTZ3 4000 A Drawout C

MPN LV839316
Active

Schneider Electric MasterPact MTZ3, LV839316, 3-pole drawout circuit breaker, 4000 A rated at 40 °C, breaking capacity, 635 VAC, without Micrologic trip unit, with ArcBlok.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839316 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch9.06 in (230 mm)
Depth16.8 in (426.8 mm)
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Electrical life cycles2800 cycles ANSI C37.50
Mechanical life cycles10000 cycles ANSI C37.50
ApplicationProtection
Safety category200 kA Icu 254 V AC 60 Hz ANSI C37.50 200 kA Icu 508 V AC 60 Hz ANSI C37.50 130 kA Icu 635 V AC 60 Hz ANSI C37.50 200 kA Icu 254 V AC 50 Hz ANSI C37.50 150 kA Icu 508 V AC 50 Hz ANSI C37.50 100 kA Icu 635 V AC 50 Hz ANSI C37.50

Product details

The Schneider Electric LV839316 is a MasterPact MTZ3 drawout circuit breaker rated for 4000 A continuous at 40 °C on a 635 VAC, 50/60 Hz network. It is a 3-pole device with an breaking capacity code, meaning it delivers 200 kA Icu at 254 V AC 60 Hz and 150 kA Icu at 508 V AC 60 Hz per ANSI C37.50 — the interrupting rating that governs its placement in a distribution switchboard. The drawout mounting allows the breaker to be racked out for maintenance without disturbing the bus connections, which is standard for large-frame ANSI gear where uptime and isolation are priorities.

The 4000 A line-rated current sets the maximum continuous load this breaker can carry without derating — sized for a main or large feeder in a 480 V industrial distribution. The integral instantaneous protection trips between 243 and 297 kA, covering bolted faults near the bus. Short-time withstand (Icw) is 100 kA for 0.5 s, which is the rating that matters for selective coordination: downstream breakers can clear a fault while this breaker holds closed, keeping the rest of the plant online. Maximum breaking time is 9 ms, and closing response is 70 ms — both fast enough to limit arc-flash energy in a properly coordinated system. Mechanical durability is 10,000 cycles; electrical durability is 2,800 cycles under ANSI C37.50 — this is a switchgear-class breaker, not a daily-operating contactor, so the cycle count reflects its role as a protective device that opens only on fault or scheduled isolation.

Integration into the switchboard

The LV839316 ships as a drawout unit on a base plate with rails. Panel builders need to account for the 16.8 in depth, 31.07 in width, and 18.8 in height — this is a full-frame breaker that occupies a dedicated cubicle in a metal-enclosed low-voltage switchboard. Connection pitch is 9.06 in (230 mm), which matches the standard bus-bar spacing for ANSI 3-pole drawout gear. The unit comes without a Micrologic trip unit, so the specifying engineer selects and installs the trip unit separately — a common practice when the protection curve (LSIG, LS, or LSI) needs to match the coordination study.

MPN
LV839316