Skip to main content
Schneider Electric LV839317

Schneider Electric LV839317 MasterPact MTZ3 5000A 3P Circuit

MPN LV839317
Active

Schneider Electric MasterPact MTZ3 ANSI circuit breaker, LV839317, 5000 A rated, 3-pole, fixed mount, breaking capacity, 635 VAC, without Micrologic trip unit, with ArcBlok.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839317 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Terminal pitch9.06 in (230 mm)
Depth16.8 in (426.8 mm)
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
Electrical life cycles2800 cycles ANSI C37.50
Mechanical life cycles10000 cycles ANSI C37.50
ApplicationProtection
Safety category200 kA Icu 254 V AC 60 Hz ANSI C37.50 200 kA Icu 508 V AC 60 Hz ANSI C37.50 130 kA Icu 635 V AC 60 Hz ANSI C37.50 200 kA Icu 254 V AC 50 Hz ANSI C37.50 150 kA Icu 508 V AC 50 Hz ANSI C37.50 100 kA Icu 635 V AC 50 Hz ANSI C37.50

Product details

The LV839317 is a Schneider Electric MasterPact MTZ3 ANSI power circuit breaker rated for a continuous line current of 5000 A at 40 °C (104 °F) — that's the full-load ampacity the main bus sees, not a thermal derate starting point. The breaking capacity code delivers 200 kA Icu at 254 V AC (60 Hz) and 150 kA Icu at 508 V AC (60 Hz) per ANSI C37.50, meaning it can safely interrupt fault currents up to those levels without upstream cascading. The integral instantaneous protection is set at 243...297 kA, so the breaker clears a bolted fault within 9 ms maximum — fast enough to limit arc-flash energy in most distribution switchgear. This is a 3-pole, fixed-mount unit designed for base plate and rail mounting in ANSI switchgear lineups. The 5000 A CT rating matches the breaker's continuous current, so the protection scheme scales directly. The 100 kA Icw for 0.5 s gives coordination engineers headroom for short-time delay settings in selective tripping schemes.

Because the trip unit is not included, the BOM must account for the separate Micrologic order code. This is a common sourcing step for MasterPact breakers — the frame and the trip unit are line items that get paired at assembly. The fixed-mount form factor means it bolts directly into the switchgear bus, not a drawout cassette, so the enclosure cutout and bus connection pitch (9.06 in / 230 mm) need to match the existing lineup.

Deployment context

The ArcBlok technology (included per the description) reduces arc-flash energy during internal faults, which helps lower incident energy levels for maintenance personnel.

MPN
LV839317