Schneider Electric LV839320

Schneider Electric LV839320 Masterpact MTZ3 50 HC, 5000A, 3P

MPN LV839320
Active

Schneider Electric Masterpact MTZ3 50 HC, switch disconnector, 5000 A, ANSI, 3P, drawout, ArcBlok.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV839320 specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Current5000 A 104 °F (40 °C)
Breaking capacity200.0 kA Icu 254 V AC 50/60 Hz with external relay ANSI C37.50 200.0 kA Icu 508 V AC 50/60 Hz with external relay ANSI C37.50 130.0 kA Icu 635 V AC 50/60 Hz with external relay ANSI C37.50
Terminal pitch9.06 in (230 mm)
Depth16.8 in (426.8 mm)
Width31.07 in (789.1 mm)
Height18.8 in (478.1 mm)
ApplicationDistribution

Product details

The Schneider Electric LV839320 is a Masterpact MTZ3 50 HC automatic switch disconnector rated for 5000 A continuous at 104 °F (40 °C) — that is the current it carries without exceeding its thermal limits in a standard electrical room environment. This is a 3-pole drawout unit built to ANSI C37.50, meaning it is designed for the North American power-distribution standard where the breaker or switch is racked into a cradle, not bolted in place. The drawout chassis and cradle (9.06 in / 230 mm connection pitch) let you isolate the unit for maintenance without unwiring the load — standard practice for switchgear lineups in industrial and commercial buildings. The interrupting ratings tell you where this part fits in a fault-coordination study: 200 kA Icu at 254 V and 508 V AC, and 130 kA Icu at 635 V AC — all with an external relay per ANSI C37.50. Those are the maximum fault currents the device can safely clear. The rated short-time withstand current [Icw] is 100 kA for 1.5 s, also per ANSI C37.50, which means it can carry that fault current for that duration without damage — essential for downstream selectivity where a slower upstream device needs time to clear. In practice, this is a main or large-feeder switch disconnector sized for high-fault-capacity switchboards.

Dimensions: 31.07 in wide, 18.8 in high, 16.8 in deep (789.1 × 478.1 × 426.8 mm). That depth includes the drawout mechanism and ArcBlok arc chamber — verify the switchgear cell depth before specifying. The chassis-mount drawout design means the fixed portion (cradle) stays wired in the cabinet; the moving portion (the switch disconnector itself) racks in and out. The 230 mm connection pitch matches standard ANSI switchgear bus spacing. Control is push-button operated on the front escutcheon, AC network powered.

MPN
LV839320