Skip to main content
Schneider Electric LV846174

LV846174 MasterPact MTZ2 3P Drawout, 2000 A, 100 kA

MPN LV846174
Active

Schneider Electric MasterPacT MTZ2, LV846174, 3P drawout circuit breaker, 2000 A at 40 °C, H2V 100 kA at 415 V AC, Category B selectivity.

$6,156.54 – $16,108.88 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846174 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846174 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth403 mm
Width441 mm
Height439 mm
Electrical life cycles8000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 8000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846174 is a MasterPact MTZ2 3-pole drawout circuit breaker, rated 2000 A at 40 °C. It's built for power distribution protection — main or tie breaker in a switchboard, protecting transformers, busbars, or large feeders. Category B selectivity means it coordinates with downstream breakers to isolate only the faulted branch.

Drawout mounting and panel fit

Drawout mounting means the breaker chassis stays wired to the bus; the moving portion slides out for maintenance or swap without pulling the whole switchboard apart. Mounting support is rails or base plate — standard for switchgear cubicles. The 441 mm width, 439 mm height, and 403 mm depth fit typical low-voltage switchgear compartments; connection pitch is 115 mm. Upside and downside connections accept front or rear terminations, so it adapts to existing busbar runs or cable ladders.

The Icw short-time withstand of 100 kA for 1 s (75 kA for 3 s) is what makes Category B selectivity work — it rides through a downstream fault long enough for the branch breaker to clear, then opens only if the fault persists. Making capacity Icm is 220 kA at 440 V, which covers the asymmetric peak on the first half-cycle. For coordination studies, the 25 ms maximum breaking time and 70 ms maximum closing response time are the numbers to plug into your time-current curves.

The MasterPact MTZ2 platform is Schneider's active drawout breaker line, so firmware revisions, spare parts, and Micrologic trip unit options remain available. If you need a different trip unit or a fixed-mount version, the MTZ2 family has those variants, but this specific order code is the 3P drawout, 2000 A, H2V, without control unit.

What the standards and environmental ratings cover

The LV846174 carries EN/IEC 60947-1, -2, and Annex H (for selectivity under earth-fault conditions), plus IEC 61557-12 for performance measurement and monitoring. Operating altitude is 0–2000 m without derating, 2000–5000 m with derating. IP30 protection means tools or fingers won't reach live parts, but it's not sealed against water — install in a cabinet. The 470 W power dissipation at rated current matters for ventilation sizing in the enclosure.

MPN