Skip to main content
Schneider Electric LV846182

Schneider Electric LV846182 MasterPact MTZ2 1250 A Circuit B

MPN LV846182
Active

Schneider Electric MasterPacT MTZ2, LV846182, fixed circuit breaker, 4P, 1250 A at 40 °C, H2V 100 kA 415 V AC.

$5,248.80 – $14,447.73 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846182 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846182 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
Electrical life cycles10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846182 is a MasterPact MTZ2 fixed circuit breaker from Schneider Electric's MasterPacT range, built for power distribution protection in industrial and commercial switchboards. The 4-pole design with neutral on the left is common for three-phase + N distribution. Selectivity category B means it coordinates with downstream breakers to isolate only the faulted branch — a key requirement for maintaining uptime on a critical bus.

Breaking capacity and what that means for your panel

The H2V performance level delivers 100 kA Ics at 415 V AC and 440 V AC.

Integration and mounting constraints

Fixed mounting on rails or a base plate. The 537 mm width, 352 mm height, and 300 mm depth — plus the 115 mm connection pitch — determine the panel cutout and busbar layout. Front or rear connections on both the line and load sides give flexibility for cable entry direction. IP30 means no protection against water ingress; install inside a switchboard enclosure rated for the environment. Derate above 2000 m altitude.

Suitability for isolation per EN/IEC 60947-2 means it provides a visible break and meets the safety requirements for disconnecting a circuit.

MPN
LV846182