Schneider Electric LV846211

LV846211 MasterPact MTZ2 4P Drawout Breaker, 1000 A, 100 kA

MPN LV846211
Active

Schneider Electric MasterPact MTZ2, LV846211, 4P drawout circuit breaker, 1000 A at 40 °C, H2V 100 kA 415 V AC, Category B.

$4,882.68 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846211 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846211 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cycles10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846211 is a 4-pole MasterPact MTZ2 drawout circuit breaker rated 1000 A at 40 °C, with an H2V performance class delivering 100 kA Ics at 440 V AC. That Ics figure — 100 kA at both 220/415 V and 440 V — means it clears a bolted fault at full rated voltage without losing the ability to carry rated current afterward, which is the difference between a one-time fuse and a reusable breaker in a main or tie position. The 12 kV Uimp impulse withstand and 100 kA Icw for 1 second confirm it holds through delayed trips on downstream faults, essential for selective coordination in a Category B installation. Drawout mounting means the breaker chassis stays wired to the bus; the removable cradle pulls for maintenance or swap without disturbing power connections.

Suitability for isolation per EN/IEC 60947-2 is confirmed, meaning the open breaker provides a visible disconnect gap for safe maintenance access.

Deployment context

Intended for power distribution protection in main switchboards, distribution panels, and generator or UPS tie points. The drawout form factor suits installations where uptime matters — a spare cradle can be pre-wired and swapped in during a fault event without de-energizing the bus. Ambient operating range of -25 to 70 °C covers most conditioned electrical rooms; storage down to -40 °C is fine for unheated warehouses.