Skip to main content
Schneider Electric LV846310

Schneider Electric LV846310 MasterPact MTZ2 20 HH, 2000 A, 3

MPN LV846310
Active

Schneider Electric MasterPact MTZ2 20 HH switch-disconnector, LV846310, 2000 A, 100 kA Icu at 440 V AC, 3P, fixed, IP30.

$5,349.51 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846310 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to EN/IEC 60947-3
Current2000 A AC 50/60 Hz 440 V
Breaking capacity100 kA Icu at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryAC-23 A AC-3
IP ratingIP30
Terminal pitch115 mm
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

LV846310 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-4-1
Depth300 mm
Width422 mm
Height352 mm
Mechanical life cycles15000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3
ApplicationDistribution
Safety categoryHH
Operating temperature-25...70 °C

Product details

Switch-disconnector for distribution — 2000 A, 100 kA Icu

The LV846310 is a fixed-mounted MasterPact MTZ2 20 HH switch-disconnector rated 2000 A at 440 V AC, with a breaking capacity of 100 kA Icu at 440 V AC. It is a 3-pole unit designed for distribution applications and certified to EN/IEC 60947-3. The part is suitable for isolation and carries a visible contact position indicator — no visible break, but the indicator confirms open/closed state.

The 2000 A continuous current and 100 kA Icu at 440 V place this in the high-current distribution tier — sized for main incoming feeders or large busbar sections where fault levels are severe. The Icw of 75 kA for 3 s and Icm of 220 kA peak confirm it can withstand and make onto high-energy faults. Utilisation categories AC-23A and AC-3 mean it handles motor switching (AC-3) and mixed resistive-inductive loads (AC-23A), though the 2000 A rating is well above typical motor branch sizes; this is a main switch, not a motor-starter component. Electrical durability is 8000 cycles for AC-23A and 6000 cycles for AC-3 at 440 V; mechanical durability is 15000 cycles with periodic preventive maintenance. Performance Level HH indicates high endurance for frequent switching.

Fixed mounting with a connection pitch of 115 mm. Dimensions: 422 mm wide, 352 mm high, 300 mm deep. IP30 protection — suitable for indoor panel installation where tools are needed to access live parts.

MPN