Skip to main content
Schneider Electric LV846314

Schneider Electric LV846314 MasterPact MTZ2 32 HH, 3200 A, 3

MPN LV846314
Active

Schneider Electric MasterPact MTZ2 32 HH switch-disconnector, LV846314, 3200 A, 3 poles, fixed mounting, 100 kA Icu at 440 V AC.

$9,896.04 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846314 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to EN/IEC 60947-3
Current3200 A AC 50/60 Hz 440 V
Breaking capacity100 kA Icu at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryAC-23 A AC-3
IP ratingIP30
Terminal pitch115 mm
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

LV846314 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-4-1
Depth300 mm
Width422 mm
Height352 mm
Electrical life cyclesAC-23 A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3
ApplicationDistribution
Safety categoryHH
Operating temperature-25...70 °C

Product details

The Schneider Electric LV846314 is a MasterPact MTZ2 32 HH switch-disconnector rated for 3200 A continuous at 440 V AC, three poles, fixed-mount chassis.

At 440 V AC the Icu is 100 kA, and the Ics is also 100 kA — a 100% Ics/Icu ratio. That means after clearing a fault at full rating the switch can be immediately reclosed without inspection or parts replacement. For a site engineer coordinating with downstream breakers, the Icw is 75 kA for 3 s or 100 kA for 1 s, which gives the upstream relay enough time to discriminate without letting the arc through.

Fixed-mount chassis, 422 mm wide by 352 mm high by 300 mm deep. IP30 front face protection; install in a cabinet with at least IP3X enclosure for the live parts.

Duty and isolation

Utilisation categories AC-23A and AC-3 cover switching of motor loads and mixed resistive-inductive loads.

MPN
LV846314