Skip to main content
Schneider Electric LV846457

Schneider Electric LV846457 MasterPact MTZ1 630A 4P Drawout

MPN LV846457
Active

Schneider Electric MasterPacT MasterPact MTZ1, LV846457, drawout circuit breaker, 4P, 630 A rated at 40 °C, H3 66 kA 415 V AC, IEC 60947-2.

$3,754.14 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846457 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch70 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The Schneider Electric LV846457 is a MasterPact MTZ1 drawout circuit breaker from the MasterPacT range, built for power distribution protection. It carries a 630 A rated current at 40 °C across four poles, with an H3 performance class delivering 66 kA breaking capacity at 415 V AC. That 66 kA rating means it clears high-fault currents on a 415 V industrial feeder without upstream devices needing to trip — a Category B selectivity device that coordinates with downstream breakers to isolate only the faulted branch.

Rated operational voltage (Ue) is 690 V AC 50/60 Hz, with insulation voltage (Ui) at 1000 V AC and impulse withstand (Uimp) at 12 kV — this breaker handles standard 400/480 V distribution and steps up to 690 V for mining or marine gear. Short-time withstand (Icw) holds 30 kA for 3 seconds, critical for selective coordination with downstream devices. Making capacity (Icm) hits 145 kA at 440 V AC, so it closes against a bolted fault without welding contacts.

Deployment context

This is a drawout breaker — the chassis stays wired to the bus, the breaker cassette slides in and out for safe swap without disturbing connections. Mounts on rails or a base plate inside a switchgear lineup. Front and rear connection options give flexibility for cable or busbar entry. IP30 protection suits enclosed switchgear; not for open washdown areas.

MPN
LV846457