Schneider Electric LV846542 MasterPact MTZ2 3P 1250 A Circui

MPN LV846542
Active

Schneider Electric MasterPact MTZ2, LV846542, 3P fixed circuit breaker, 1250 A at 40 °C, 50 kA Icu at 1150 V AC, H10 performance, rear connections.

$10,650.49 – $11,183.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846542 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage1150 V AC 50/60 Hz
Insulation voltage ui1250 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topRear
Connection surface bottomRear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846542 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width422 mm
Height352 mm
Electrical life cycles500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical life cycles25000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 12 H10 — 1250 A Fixed Circuit Breaker

The Schneider Electric LV846542 is a MasterPact MTZ2 3-pole fixed circuit breaker rated for 1250 A at 40 °C, with a 50 kA ultimate breaking capacity (Icu) at 1150 V AC. It belongs to the H10 performance class, meaning it delivers 50 kA at the full rated voltage — the figure that governs fault interruption in a 1150 V distribution panel. Category B selectivity per IEC 60947-2 allows this breaker to coordinate with downstream devices, so a fault on a branch clears without taking the main bus off-line. The short-time withstand (Icw) holds 50 kA for up to 3 seconds, which matters for selective coordination schemes where the breaker must ride through a delayed trip on the feeder. Making capacity (Icm) is 105 kA at 1150 V — the peak let-through the contacts must close into without welding. It ships without a control unit, so the buyer specifies the trip unit separately based on the protection profile needed (LSIG, LSI, or electronic). The frame accepts sensor ratings from 630 A through 1250 A, giving some flexibility if the downstream load changes.

Deployment and Integration

Mounts on rails or a base plate in a fixed position — no draw-out cradle. Dimensions are 422 mm wide by 352 mm high by 300 mm deep, with a 115 mm connection pitch. Altitude derating applies above 2000 m — no derating needed below that. Power dissipation is 100 W at rated current, which must be factored into the enclosure ventilation design.

Compliance documentation covers EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. No UL or CSA listing is stated in the evidence — verify with the local Schneider office if a UL 489 mark is required for the installation.

MPN
LV846542