Skip to main content
Schneider Electric LV846544

LV846544 MasterPact MTZ2 2000A 3P 50kA @1150V AC Circuit Bre

MPN LV846544
Active

Schneider Electric MasterPact MTZ2, LV846544, fixed 3P circuit breaker, 2000 A at 40 °C, H10 performance class (50 kA Icu/Ics at 1150 V AC), rear-connect, push-button control.

$10,650.49 – $11,183.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846544 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage1150 V AC 50/60 Hz
Insulation voltage ui1250 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topRear
Connection surface bottomRear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846544 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width422 mm
Height352 mm
Electrical life cycles500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-2
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846544 is a MasterPact MTZ2 fixed-mount, 3-pole air circuit breaker rated for 2000 A at 40 °C, with a 50 kA ultimate breaking capacity (Icu) and 50 kA service breaking capacity (Ics) at 1150 V AC, 50/60 Hz. It sits in the H10 performance tier, meaning it clears 50 kA faults without upstream coordination issues — the 50 kA Ics equals the Icu, so it can reclose after a fault at full rating, which matters for critical-feed continuity. It's a Category B breaker per IEC 60947-2, designed for selective coordination with downstream devices — the short-time withstand (Icw) of 50 kA for 1 s lets it ride through a fault long enough for a downstream breaker to clear, keeping the main bus live.

Rated at 2000 A continuous, with a 1250 V insulation voltage (Ui) and 1150 V operational voltage (Ue). The 12 kV impulse withstand (Uimp) covers surge coordination in industrial distribution panels. That's typical for a large-frame power breaker — it's not intended for frequent switching, but for protection and isolation. The 250 W power dissipation at rated current matters for panel cooling calculations.

Fixed-mount on rails or a base plate, with rear connections both top and bottom — that's the standard for switchboard or MCC integration where you want bus-bar connections behind the breaker. The 115 mm connection pitch matches common bus-bar drilling patterns. IP30 enclosure protection means it's for indoor, dry locations; no washdown rating. Push-button control, no electronic control unit — this is a basic thermal-magnetic or micrologic trip unit carrier (the sensor rating covers 1000 A to 2000 A, so the trip unit is field-selectable). The 25 ms maximum break time and 70 ms max closing time are standard for this class.

Compliance and isolation

Certified to EN/IEC 60947-1, -2, and Annex H for selectivity, plus IEC 61557-12 for performance. Suitability for isolation is confirmed — it can be used as a disconnecting means per code. Pollution degree 3 (industrial environment) per IEC 60947-1. Operating altitude to 2000 m without derating, to 5000 m with derating.

MPN