Skip to main content
Schneider Electric LV846556

Schneider LV846556 MasterPact MTZ2 3200A, 50kA at 1150V

MPN LV846556
Active

Schneider Electric MasterPact MTZ2, LV846556, fixed 4P circuit breaker, 3200 A rated, 50 kA Ics at 1150 V AC, H10 performance, rear connection.

$12,612.70 – $13,243.34 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846556 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage1150 V AC 50/60 Hz
Insulation voltage ui1250 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topRear
Connection surface bottomRear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846556 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
Electrical life cycles500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846556 is a Schneider Electric MasterPact MTZ2 fixed-mounted, 4-pole air circuit breaker with a 3200 A rated current (In) at 40 °C, designed for power distribution protection in main switchboards and industrial feeders. It carries a Category B selectivity classification (EN/IEC 60947-2), meaning it can discriminate with downstream breakers to keep a fault isolated to the smallest section of the installation — critical for maintaining uptime on a production line or critical process. The H10 performance grade delivers a 50 kA Ics (service breaking capacity) at 1150 V AC, 50/60 Hz, with a corresponding Icm (making capacity) of 105 kA at the same voltage. That 50 kA Ics is the breaker's ability to clear a fault and be immediately reclosed — not a one-shot sacrificial rating. The Icw (short-time withstand) is 50 kA for up to 3 seconds, which gives downstream protection devices time to clear a fault before the main breaker trips, supporting selective coordination in a multi-tier distribution system.

Physical integration — fixed mount, rear connection, 537 mm wide

Fixed-mounted on rails or a base plate, with rear connection on both the line and load sides. The 537 mm width, 352 mm height, and 300 mm depth define the panel cutout and enclosure size needed — this is a large-frame breaker that requires a dedicated compartment in the switchboard, not a DIN-rail unit. Connection pitch is 115 mm, matching standard busbar or cable lug spacing for 3200 A class terminations. Neutral position is left, 4-pole (3 phases + neutral switched). Rated operational voltage is 1150 V AC — this is a 1000 V-class breaker, common in heavy industrial and mining installations where 690 V or 1000 V distribution is used.

Durability and operating conditions

Mechanical durability is 20,000 cycles with periodic preventive maintenance; electrical durability is 500 cycles at 1150 V AC, 50/60 Hz per EN/IEC 60947-2. Maximum breaking time is 25 ms, closing response time is 70 ms. Operating altitude is 0–2000 m without derating; above 2000 m up to 5000 m requires derating per the manufacturer's guidelines. The breaker is supplied without a control unit — the Micrologic trip unit is ordered separately or as part of a configured assembly, so verify the trip unit type (A, E, P, or H) when specifying the complete breaker.

MPN