Skip to main content
Schneider Electric LV846557

Schneider Electric LV846557 MasterPact MTZ2 4000 A, 4P Circu

MPN LV846557
Active

Schneider Electric MasterPact MTZ2, fixed circuit breaker, 4P, 4000 A at 40 °C, H10 50 kA 1150 V AC, Category B, rear connections, IP30.

$12,612.70 – $13,243.34 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846557 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage1150 V AC 50/60 Hz
Insulation voltage ui1250 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topRear
Connection surface bottomRear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846557 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
Electrical life cycles500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 40 H10 — 4000 A fixed breaker

The LV846557 is a fixed-mount MasterPact MTZ2 circuit breaker, 4 poles, rated 4000 A at 40 °C. It belongs to the H10 performance class, delivering 50 kA service breaking capacity (Ics) at 1150 V AC — the voltage level common in large industrial distribution and data-center power paths. Category B selectivity means it coordinates downstream with full discrimination up to its Icu, so a fault on a branch feeder clears without dropping the main bus.

The sensor rating range (2000 A / 2500 A / 3200 A / 4000 A) lets you match the electronic trip unit to the actual load, not the breaker frame. Ics of 50 kA at 1150 V AC is the service rating: the breaker clears that fault and is expected to be usable afterward, not just survive once. Icw of 50 kA for 3 seconds supports selective coordination with downstream feeders — the breaker holds closed long enough for the branch device to clear. Rear connections both top and bottom suit switchboard or drawout-cassette installations where cable access is from the back. Dimensions 537 mm wide × 352 mm high × 300 mm deep; the 115 mm connection pitch matches standard busbar and cable-lug spacing for this frame size.

Designed to EN/IEC 60947-1 and 60947-2, plus Annex H for power circuit-breaker coordination and IEC 61557-12 for measuring equipment. Isolation capability is confirmed per EN/IEC 60947-2 — the breaker can serve as a visible disconnect when open.

MPN
LV846557