Skip to main content
Schneider Electric LV847207

Schneider Electric LV847207 MasterPact MTZ1 Drawout Circuit

MPN LV847207
Active

Schneider Electric MasterPact MTZ1, LV847207, drawout circuit breaker, 4P, 630 A at 40 °C, performance 150 kA at 415 V AC, IEC 60947-2.

$5,125.22 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV847207 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch70 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Mechanical life cycles12500 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The Schneider Electric LV847207 is a MasterPact MTZ1 drawout circuit breaker rated 630 A at 40 °C, with an performance class delivering 150 kA Ics at 415 V AC. It's a 4-pole unit (neutral left) in a drawout chassis, designed for main or feeder protection in power distribution. Key specs: rated insulation voltage 1000 V AC, operational voltage 690 V AC, impulse withstand 12 kV. The Icw is 10 kA for 0.5 s, and the Icm making capacity hits 330 kA at 415 V. Breaking time maxes at 9 ms, closing at 50 ms. Electrical durability: 3000 cycles at 690 V AC-23A, 6000 at 440 V. Mechanical durability is 12,500 cycles with periodic maintenance.

Drawout mounting means the breaker chassis stays wired to the bus; the moving portion pulls out for maintenance or swap without disturbing connections. Mounts on rails or base plate with a 70 mm connection pitch. Dimensions with chassis: 291 mm deep, 358 mm wide, 322 mm high. Without chassis: 207.5 mm deep, 306.5 mm wide, 259.5 mm high. Plan for the full chassis footprint in the switchgear lineup.

Compliance & Lifecycle

Power dissipation is 115 W at rated current — factor that into enclosure cooling. Control is push-button type; this variant ships without a control unit (Micrologic trip unit ordered separately).

MPN