Skip to main content
Schneider Electric LV847271

Schneider Electric LV847271 MasterPact MTZ2 10 HA10, 1000 A,

MPN LV847271
Active

Schneider Electric MasterPact MTZ2 10 HA10 switch disconnector, LV847271, 1000 A, 1150 V AC, 105 kA Icm, 4P, fixed mount, EN/IEC 60947-3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV847271 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage1150 V AC 50/60 Hz conforming to EN/IEC 60947-3
Insulation voltage ui1250 V AC 50/60 Hz conforming to EN/IEC 60947-3
Current1000 A AC 50/60 Hz 1150 V
Utilization categoryAC-23 A AC-3
IP ratingIP30
Terminal pitch115 mm
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV847271 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-4-1
Depth300 mm
Width537 mm
Height352 mm
Electrical life cyclesAC-23 A: 500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-3
ApplicationDistribution
Safety categoryHA10
Operating temperature-25...70 °C

Product details

The LV847271 is a MasterPact MTZ2 10 HA10 switch disconnector rated 1000 A at 1150 V AC, 50/60 Hz, in a 4-pole fixed-mount configuration. It is designed for distribution applications per EN/IEC 60947-3, with a making capacity of 105 kA peak at 1150 V AC and a short-time withstand of 50 kA for 1 s or 3 s. The HA10 performance level indicates a high-endurance duty class suited for frequent switching of motor loads (AC-3) and mixed resistive-inductive loads (AC-23A).

The 1000 A continuous rating at 1150 V AC sets the thermal capacity for a main feeder or large motor circuit. The AC-23A / AC-3 utilisation categories mean it handles the inrush of motors and mixed loads without derating — AC-23A covers occasional switching of motors and other highly inductive loads, while AC-3 covers frequent motor starting. The 105 kA peak making capacity (Icm) and 50 kA short-time withstand (Icw) for 1 s or 3 s define the fault-closing and fault-withstand capability; this switch disconnector can close onto a bolted fault and hold the let-through until an upstream breaker clears, which is critical for selective coordination in a distribution panel. The 12 kV rated impulse withstand voltage (Uimp) and insulation voltage of 1250 V AC confirm the part is suitable for 1000 V class systems with typical surge levels. The isolation function is certified per EN/IEC 60947-3, with a visible contact position indicator and a push-button control. The 25 000 mechanical cycles with periodic preventive maintenance and 500 electrical cycles at 1150 V AC (AC-23A) set the service life; for high-cycle motor-starting applications, plan maintenance intervals around the electrical endurance figure.

Deployment context

Fixed-mount chassis with a 115 mm connection pitch and overall dimensions of 537 mm wide × 352 mm high × 300 mm deep. The 4-pole configuration (3 phases + neutral) suits three-phase distribution with a switched neutral, common in North American and IEC panel designs.

MPN
LV847271