Skip to main content
Schneider Electric LV848104

Schneider LV848104 MasterPact MTZ3 50 H2, 5000 A, 150 kA

MPN LV848104
Active

Schneider Electric MasterPact MTZ3 50 H2, LV848104, fixed-mount circuit breaker, 4P, 5000 A at 40 °C, H2 performance 150 kA at 415 V AC, rear connections.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848104 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch230 mm
Connection surface topRear
Connection surface bottomRear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV848104 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width997 mm
Height352 mm
Mechanical life cycles10000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV848104 is a fixed-mount MasterPact MTZ3 50 H2 air circuit breaker in a 4-pole configuration. Its 5000 A rated current at 40 °C sets the continuous ampacity for the main feeder — size the upstream transformer and busway for that full-load current, not less. The H2 performance class delivers 150 kA Ics at 415 V AC, meaning after clearing a fault at that level the breaker is rated to switch the load back on without inspection or part replacement. That is the difference between a one-hour outage and a shift-long repair. Category B selectivity means the breaker coordinates with downstream devices so only the faulted branch opens — the main stays closed and the rest of the plant keeps running. The 100 kA Icw for 3 seconds tells you it can pass fault current while the downstream breaker clears, which is the core requirement for a fully selective distribution scheme.

This is a fixed-mount breaker — no draw-out cradle. It bolts to a base plate or rails inside the switchgear lineup. Both upside and downside connections are rear, so cable or busbar entry and exit happen behind the panel. The 230 mm connection pitch sets the busbar drilling pattern. Neutral sits on the right. Overall dimensions: 997 mm wide, 352 mm high, 300 mm deep. That depth is the chassis only — allow additional clearance for rear connections and cable bending radius when sizing the enclosure. This is standard for indoor switchgear. If the installation sees washdown or outdoor exposure, it needs a higher-rated enclosure around it.

For a BOM-critical 5000 A feeder, this is the part to lock in.

Electrical durability: 6000 cycles in AC-3 duty at 440/690 V. Mechanical durability: 10,000 cycles with periodic preventive maintenance. Maximum breaking time is 25 ms; maximum closing response time is 80 ms. Power dissipation at rated current is 420 W — factor that into the switchroom HVAC load.

MPN
LV848104